AR-M350 SIMULATIONS 10-13
<List of set values>
<List of set values>
MCSS3
MP tray size detection 3
MCSS2
MP tray size detection 2
MCSS1
MP tray size detection 1
MCSPD
MP tray remaining quantity
detection
MCLUD
MP tray upper limit
detection
MCPED
MP tray paper empty
detection
DPFD1
MP tray transport detection
4-3
Purpose
Operation test, check
Function (Content)
Used to check the operation under load in the
paper feed section (desk paper feed/large
capacity trays) and their control circuits.
Section
Paper feed
Item
Operation
Operation/Procedure Select with 10 digit key pad.
3-tray desk
LCC
1 DLUM2 Desk lift-up motor 2
1 TLUM2
LCC lift-up motor 2
2 DLUM1 Desk lift-up motor 1
2 TLUM1
LCC lift-up motor 1
3 MCLUM Desk multi lift-up
motor
3 MCLUM LCC multi lift-up
motor
4 DPFCL
Desk paper transport
clutch
4 TPFCL
LCC transport clutch
5 DPCL2
Desk paper feed
clutch 2
5 TPCL2
LCC paper feed
clutch 2
6 DPCL1
Desk paper feed
clutch 1
6 TPCL1
LCC paper feed
clutch 1
7 MCPCL Desk multi paper feed
clutch
7 MCPCL LCC multi paper feed
clutch
8 DMM
Desk transport motor
8 TMM
LCC transport motor
3-tray desk
LCC
SIMULATION 4-3
DESK/LCC LOAD TEST. SELECT 1- , AND PRESS START.
1.
2.
2
SIMULATION 4-3
DESK/LCC LOAD TEST. EXECUTING...
1.
2.
2
Press [START] key to get started.
Press [CUSTOM SETTING] key to stop.
Main code 5
5-1
Purpose
Operation test, check
Function (Content)
Used to check the operations of the lamps and
LCD on the operation panel and their control
circuits.
Section
Operation (display, operation)
Item
Operation
Operation/Procedure All LEDs are ON. The LCD contrast changes
Max/Min every 2sec.
5-2
Purpose
Operation test, check
Function (Content)
Used to check the operations of the heater lamp
and its control circuit.
Section
Fusing
Item
Operation
Operation/Procedure Select with 10 digit key pad. The lamp repeat
ON/OFF every 500ms 5 times.
1
Heater lamp 1 (Lower)
2
Heater lamp 2 (Upper)
SIMULATION 5-1
SIMULATION 5-1
After 6.0 sec
Press [CUSTOM SETTING] key to stop.
SIMULATION 5-2
HEATER LAMP TEST. SELECT 1-2, AND PRESS START.
1.HL1(LOWER)
2.HL2(UPPER)
2
SIMULATION 5-2
HEATER LAMP TEST. EXECUTING...
1.HL1(LOWER)
2.HL2(UPPER)
2
Press [START] key to get started.
Press [CUSTOM SETTING] key to stop.
Repeats specified times and stops.
!"#$%&