AR-M350 ADJUSTMENTS 9-9
(1) Test chart setting
1) Place a test chart (UKOG-0162FCZZ) on the original table as shown
below.
2) Place several sheets of A3 (11 x 17) white paper
(Sharp's specified paper) on the test chart at the rear reference.
Test chart comparison
(2) Density adjustment procedure
a. Collective adjustment of two or more copy quality modes
Normally this adjustment is performed with SIM 46-2. In this method, two
or more copy density adjustments in different modes can be adjusted
collectively.
1) Execute SIM 46-2.
(Binary value mode)
2) Press the COPY button to make a copy.
Check that the copy density is as shown in the table below.
If not, change the adjustment value.
•Adjustment spec
If the copy density is too light, increase the adjustment value.
If the copy density is too dark, decrease the adjustment value.
Adjustment range: 30 - 170
b. Individual adjustment of each copy quality mode
This adjustment is used when a different density level for different copy
UKOG-0162FCZZ
DENSITY No.
1
2
3
4
5
6
7
8
9
10
W
UKOG-0089CSZZ
DENSITY No.
0.1
0.2
0.3
0.5 1.9
0
KODAK GRAY
SCALE
1
2
3
4
19
A
SHARP
CORPORATION
MADE IN JAPAN
UKOG-0162FCZZ
1
10
W
2
3
4
5
6
7
8
9
Quality mode
Linked simulation data
AE3.0 (AE)
CH3.0 (Character)
sim46-9
MIX3.0 (Character/Photo)
sim46-10
PH3.0 (Photo)
sim46-11
Mode
EXP.
Chart
No.
Adjustment
level
Chart
No.
Adjustment
level
Character
3
3
Copied
2
Not copied
Character/
Photo
3
3
Copied
2
Not copied
Photo
3
3
Copied
2
Not copied
Auto
3
Copied
2
Not copied
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 0-6, AND PRESS START.
0. TRAY SELECT
1. COPY START
2. EXP LEVEL
3. AE 3.0
4. CH 3.0
5. MIX 3.0
6. PHOTO 3.0
1
50
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. MFT
1
SIMULATION 46-2
EXP. LEVEL SETUP (2). NOW COPYING.
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 3-6, AND PRESS START.
(EXP. LEVEL SELECT)
3. AE 3.0 4. CH 3.0
5. MIX 3.0 6. PHOTO 3.0
1
50
50
1
1
50
50
SIMULATION 46-2
EXP. LEVEL SETUP (2),INPUT VALUE 0-99, AND PRESS START.
3. AE 3.0
Press [CUSTOM SETTING] key.
Select other than 0 - 2,
and press [START] key.
Select 1, and
press [START] key.
Select 2, and
press [START] key.
Select 0, and
press [START] key.
Press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
Press [START] key or
press [CUSTOME SETTING] key.
Press [CUSTOM SETTING] key.
Or copying is terminated.
!"#$%