AR-M350 SIMULATIONS 10-44
<Set values>
<Set value 1>
<AE mode>
<AE fixed mode>
Default : 0
<Set value>
46-18
Purpose
Adjustment
Function (Content)
Used to adjust gamma (density gradient) in each
copy mode.
Section
Item
Picture quality
Operation/Procedure 1) Change the gamma value.
The current set value is displayed on the right
of each item. (Set value)
2) Set the gamma with 10 digit key pad.
Press START to store the set value.
(Default 64, set range 0 - 127)
3) The greater the value is, the greater the
gradient is.
1
AE mode
2
Text mode
3
Text/Photo mode
4
Photo mode
46-19
Purpose
Adjustment
Function (Content)
Used to adjust gamma (density gradient) in the
auto copy mode and to set the density detection
area, and to set the image process mode.
Section
Item
Picture quality
Operation/Procedure 1) Change the control method of exposure
mode.
The current set value is displayed on the right
of each item. (Set value 1)
2) Set with 10 digit key pad. (AE mode)
3) Set with 10 digit key pad. (AE fixed mode)
SIMULATION 46-18
GAMMA SETUP. SELECT 1-4, AND PRESS START.
1. AE
2. CHARA 3. MIX
4. PHOTO
SIMULATION 46-18
GAMMA SETUP.INPUT VALUE 0-127, AND PRESS START.
1. AE
64
64
64
64
64
Press [CUSTOM SETTING] key.
Press [START] key.
SIMULATION 46-19
EXP. MODE SETUP . SELECT 1-2, AND PRESS START.
1. AE MODE
2. AE STOP MODE
SIMULATION 46-19
EXP. MODE SETUP . INPUT VALUE 1-2, AND PRESS START.
1. AE MODE
1
SIMULATION 46-19
EXP. MODE SETUP . INPUT VALUE 0-1, AND PRESS START.
2. AE STOP MODE
0
0
1
Press [CUSTOM SETTING] key.
Select 1, and
press [START] key.
Select 2, and
press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
1
AE mode
2
AE fixed mode
1
Picture priority mode
2
Toner consumption priority mode
0
AE fixed function : OFF
1
AE fixed function : ON
46-20
Purpose
Adjustment
Function (Content)
Used to adjust the copy density correction in the
SPF/DSPF copy mode for the document table
copy mode. This adjustment is made so that the
copy density becomes the same as that in the
document table copy mode.
Section
Item
Picture quality
Operation/Procedure 1) The exposure correction of OC and SPF is
performed. The current set value is displayed
on the right of each item. (Set value)
2) Set with 10 digit key pad.
(Default 128, set range 0 -255)
3) Add "Set value - 128" to the shading
adjustment value (SIM 46-17).
1
SPF (surface CCD odd pixel)
2
SPF (surface CCD even pixel)
3
DSPF (back surface)
SIMULATION 46-20
OC/SPF EXP. ADJUSTMENT. SELECT 1-3, AND PRESS START.
1. SPF(ODD)
2. SPF (EVEN)
3. DSPF
1
SIMULATION 46-20
OC/SPF EXP. ADJUSTMENT. INPUT VALUE 0-255, AND PRESS
START.
1. SPF(ODD)
128
128
128
128
Press [CUSTOM SETTING] key.
Press [START] key.
!" #$%&