AR-M350 SIMULATIONS 10-54
<List of set values 1>
<List of display values 1>
<List of set values 2>
*
The selected tray is registered as an initial set value in the initial
screen.
Main code 51
51-2
Purpose
Adjustment
Function (Content)
Used to adjust the contact pressure of paper on
the resist roller in each section (machine paper
feed, duplex paper feed, SPF paper feed).
(This adjustment is required when the print
image position varies or when paper jam occurs
frequently.)
Section
Paper transport
(paper exit, switchback, transport)
Item
Operation
Operation/Procedure Perform the resist quantity adjustment.
1) The current set value is highlighted on the
right of each item. In this screen, be sure to
select "1: COPY START." (Set value: 1)
2) Enter the correction value with 10 digit key
pad.
Press P to store the set value.
3) When the value is increased by 1, the resist
quantity is changed by 1ms.
4) Press START to start copying and store the
set value. (Display value: 1)
5) Select a paper feed tray. (Set value 2)
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0. TRAY SELECT
1
1.PRINT START
2. TRAY1
50
3. TRAY2
50
4. DESK
50
5. BPT
50
6. ADU
50
7. SPF(HIGH)
50
8. SPF(LOW)
50
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
1. TRAY1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
(ABOVE +10: DUPLEX MODE)
Press [CUSTOM SETTING] key.
Select 0 or 1,
and press [START] key.
Select 1, and
press [START] key.
Select 0, and
press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
Press [CUSTOM SETTING] key.
Or copying is terminated.
45PPM 35PPM
0 TRAY
SELECT
Paper feed tray selection (1 - 5)
1 PRINT
START
Copy start (Initial value)
2 TRAY1
Tray 1 resist adjustment value
60
65
3 TRAY2
Tray 2 resist adjustment value
50
55
4 DESK
Desk resist adjustment value
50
55
5 BPT
Manual tray resist adjustment value
55
60
6 ADU
ADU resist adjustment value
50
55
7 SPF(HIGH) SPF resist adjustment value
(High speed)
50
50
8 SPF(LOW) SPF resist adjustment value
(Low speed)
50
50
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
1
TRAY1
11
TRAY1 with Duplex
2
TRAY2
12
TRAY2 with Duplex
3
TRAY3
13
TRAY3 with Duplex
4
TRAY4
14
TRAY4 with Duplex
5
Manual feed
15
Manual feed with Duplex
* !" #$%&'