CHAPTER 5.
ADJUSTMENT
[1] ADJUSTMENT PROCEDURE
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should become improper or an adjustment is
required due to part replacement, make an adjustment according to the following procedure.
1. After replacement of any PWB unit and/or IC for repair, please note the following.
•
When replacing the following units, make sure to prepare the new units loaded with updated software.
•
When replacing the LCD control PWB, perform the VCOM adjustment.
2. Upgrading of each microprocessor software
CAUTION: Never “POWER OFF” the unit when software upgrade is ongoing.
Otherwise the system may be damaged beyond recovery.
2.1. Software version upgrade
The main software can be upgraded by using a general-purpose USB Memory.
The followings are the procedures for upgrading, explained separately for the main software, monitor microprocessor software.
2.2. Main software version upgrade
2.2.1 Get ready before you start
•
USB Memory of 256MB or higher capacity.
•
PC running on Windows operating system.
•
USB Memory reader/writer or PC with a USB port.
•
The file system of a USB memory is FAT. (FAT32 supports)
•
Use the USB memory without other functions. (lock and memory reader...etc)
2.2.2 Preparations
To upgrade the main software, it is necessary to get ready the USB Memory for version upgrade before you start.
Follow the steps below and create the USB Memory for version upgrade.
1. Copy the file BUFQ_C_xxx.img for version upgrade to the root directory (folder) of the USB Memory.
NOTE: In the USB Memory drive, do not store other folders or unrelated files, or more than one file for version upgrade.
Now the USB Memory for version upgrade is ready.
MAIN Unit:
DKEYMG577FM02
: LC-60/70EQ30U
Содержание AQUOS LC-60EQ30U
Страница 7: ...LC 60 70EQ30U 2 1 LC 60EQ30U Service Manual CHAPTER 2 OPERATION MANUAL 1 OPERATION MANUAL ...
Страница 8: ...LC 60 70EQ30U 2 2 㪣㪚㪄㪍㪇㪜㪨㪊㪇㪬 ...
Страница 9: ...LC 60 70EQ30U 2 3 ...
Страница 10: ...LC 60 70EQ30U 2 4 ...
Страница 11: ...LC 60 70EQ30U 3 1 LC 60EQ30U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS LC 60EQ30U ...
Страница 21: ...LC 60 70EQ30U 4 9 3 The location putting on the heat measure sheet 1 Pegar PSPAZC805WJKZ x2 COOLER 25X25X8t ...
Страница 73: ...LC 60 70EQ30U ...