LC-60/70LE660U,C6600U
6 – 2
3. New method
LED flashing timing chart at the time of an error
1) POWER indicator
Note
2) Inverter/Lamp failure details (POWER Green LED Flashes once, and DPC/SLEEP LED flashes)
Note
3) Power failure details (POWER Green LED Flashes twice, and DPC/SLEEP LED flashes)
Note
Error type
Center icon LED operation
Pins are monitor microcomputer pins unless otherwise
specified.
Inverter/Lamp failure
Flashes fast once
H: On
L: Off
Inverter/Lamp failure details is detected.
Power supply failure
Flashes fast twice
H: On
L: Off
Power failure details is detected.
Main CPU Communica-
tion failure
Flashes fast 3 times
H: On
L: Off
Communication failure details is detected.
Other failure
Flashes fast 4 times
H: On
L: Off
Other failure details is detected.
Error type
Center icon LED operation
Pins are monitor microcomputer pins unless otherwise
specified.
Lamp failure
Flashes fast once
H: On
L: Off
ERR_PNL (19pin): Hi failure. Confirmed after 8 consecutive
detections at 64 msec intervals (detected only when the back-
light is on).
Note that after five detection counts, the lamp cannot be acti-
vated except in the monitor process.
Accumulated counts are cleared to 0 by the setting in the pro-
cess A.
Error type
Center icon LED operation
Pins are monitor microcomputer pins unless otherwise
specified.
PS_ON
AC_DET failure
Flashes fast once
H: On
L: Off
AC_DET (28pin) failure (L).
If error is detected during start-up or operation, the power is
turned on again by interrupt (instantaneous blackout process-
ing).
D_POW
Main 12V failure
Flashes fast twice
H: On
L: Off
DET_12V (32pin) failure (L). Main 12V is not applied.
If error is detected during start-up or operation, the power is
turned on again by polling.
D_POW
Digital 3.3V failure
Flashes fast 3 times
H: On
L: Off
DET_D3V3 (33pin) failure (L). Digital 3.3V is not applied.
If error is detected during start-up or operation, the power is
turned on again by polling.
PANEL_POW
Panel 12V failure
Flashes fast 5 times
H: On
L: Off
DET_PNL_12V (34pin) failure (L). Panel power is not applied.
Detection is started after turning on the panel power and
receiving command; the power is turned off by polling.
TCON_POW
TCON Power failure
Flashes fast 5 times
H: On
L: Off
DET_POW_T (34pin) failure (L). TCON power is not applied.
Detection is started after turning on the panel power and
receiving command; the power is turned off by polling.
DRC_POW
DRC Power failure
Flashes fast 6 times
H: On
L: Off
DET_POW_D (26pin) failure (L). DRC power is not applied.
Detection is started after turning on the panel power and
receiving command; the power is turned off by polling.
FRC_POW
FRC Power failure
Flashes fast 7 times
H: On
L: Off
DET_POW_F (24pin) failure (L). FRC power is not applied.
Detection is started after turning on the panel power and
receiving command; the power is turned off by polling.
Содержание Aquos LC-60C6600U
Страница 6: ...LC 60 70LE660U C6600U 1 1 LC 60LE660U Service Manual CHAPTER 1 SPECIFICATIONS 1 SPECIFICATIONS ...
Страница 7: ...LC 60 70LE660U C6600U 2 1 LC 60LE660U Service Manual CHAPTER 2 OPERATION MANUAL 1 OPERATION MANUAL ...
Страница 8: ...LC 60 70LE660U C6600U 2 2 3 ...
Страница 9: ...LC 60 70LE660U C6600U 2 3 ...
Страница 10: ...LC 60 70LE660U C6600U 2 4 ...
Страница 11: ...LC 60 70LE660U C6600U 3 1 LC 60LE660U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS ...
Страница 54: ...LC 60 70LE660U C6600U 7 3 ...
Страница 71: ...LC 60 70LE660U C6600U ...