LC-60/70LE660U,C6600U
6 – 4
[3] TROUBLESHOOTING TABLE
•
LED Backlight does not turn on.
If it is not an error of power supply/LED driver,
It is start-up in the lamp error disregard mode.
Do you start?
YES
When main unit is replaced, does it start normally?
YES
NO
Replace main unit.
When LCD control unit is replaced, does it start normally?
YES
NO
Replace LCD control unit.
When the parts in the panel can be replaced.
→
Replace all LED-bars in the panel module.
When the parts in the panel cannot be replaced.
→
Replace panel module.
If it is not an error of power supply/LED driver,
It is start-up in the lamp error disregard mode.
Do you start?
NO
When power supply unit is replaced, does it start normally?
YES
NO
Replace power supply unit.
When main unit is replaced, does it start normally?
YES
NO
Replace main unit.
When LCD control unit is replaced, does it start normally?
YES
NO
Replace LCD control unit.
When the parts in the panel can be replaced.
→
Replace all LED-bars in the panel module.
When the parts in the panel cannot be replaced.
→
Replace panel module.
Содержание Aquos LC-60C6600U
Страница 6: ...LC 60 70LE660U C6600U 1 1 LC 60LE660U Service Manual CHAPTER 1 SPECIFICATIONS 1 SPECIFICATIONS ...
Страница 7: ...LC 60 70LE660U C6600U 2 1 LC 60LE660U Service Manual CHAPTER 2 OPERATION MANUAL 1 OPERATION MANUAL ...
Страница 8: ...LC 60 70LE660U C6600U 2 2 3 ...
Страница 9: ...LC 60 70LE660U C6600U 2 3 ...
Страница 10: ...LC 60 70LE660U C6600U 2 4 ...
Страница 11: ...LC 60 70LE660U C6600U 3 1 LC 60LE660U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS ...
Страница 54: ...LC 60 70LE660U C6600U 7 3 ...
Страница 71: ...LC 60 70LE660U C6600U ...