28
* Factory default settings are indicated with an asterisk (*).
5
Press the start (
) key. The right-hand number in the display
will be steadily lit and the entered value will be stored.
6
Press the light (
) or dark (
) key to return to the normal
copy mode.
DISPLAYING TOTAL NUMBER OF COPIES
Use the following procedure to display the total number of copies.
1
Press the clear (
) key to reset the display to zero.
2
Press and hold down the clear (
) key for approximately 5
seconds. The total number of copies will appear in two steps,
each with three digits.
Example: Total number of copies is 1,234.
Program
No.
Mode
Parameters
1
Auto clear time
0
OFF, 1
10sec., 2
30sec.
*3
60sec.,
4
90sec.,
5
120sec.
2
Preheat mode
*0
30sec., 1
60sec., 2
90sec.
3
Auto power shut- off
timer
0
2min., *1
5min., 2
15min.
3
30min. 4
60 min. 5
120min.
4
Stream feeding
mode
0
OFF, *1
ON
5
Auto power shut- off
mode
0
OFF, *1
ON
6
Resolution of AUTO
& MANUAL mode
*0
300dpi, 1
600dpi
Program No. 4 can be selected on the AL-1225.
To change the setting or to set another mode, press the clear
(
) key. The unit will return to step 2.