10
26MR70
MTS ADJUSTMENT
MTS Level Adjustment
1. Feed the following monaural signal to pin (14) of
IC3001.
Monaural signal: 300Hz, 245mVrms
2. Connect the rms voltmeter to pin (39) of IC3001.
3. Enter the service mode and select the service
adjustment "M01".
4. Adjust the data so that the rms voltmeter reads 490
±10mVrms.
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in betw een
po) side of C3005 and ground.
4. Enter the service mode and select the service
adjustment "M02"
5. Adjust the data so that the frequency counter reads
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of
IC3001 .
Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service
adjustment "M03".
3. Adjust the data at the point where "OK" appears on
the screen. The "OK" represents the approximate
center of the adjustable range of the data.
Separation Adjustment
1. Connect the rms voltmeter to pin (39) of IC3001.
2. Receive the following composite stereo signal 1.
Composite stereo signal: 30% modulation, left
channel only, noise reduction on, 300Hz
3. Enter the service mode and select the service
adjustment "M04".
4. Adjust the data until the AC voltage reading of the
rms voltmeter is minimum.
5. Receive the following composite stereo signal 2.
Stereo signal: 30% modulation, left channel only,
noise reduction on, 3kHz
6. Enter the service mode and select the service
adjustment "M05".
7. Adjust the data until the AC voltage reading of the
rms voltmeter is minimum.
8. Take the abo ve steps 1 thr u 7 again
for fine
adjustment.
Vertical-Size, V-Linearity and
V-S Correction Adjustments
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment
"D02"
for Vertical
Size, "D05"
for
V-
Linearity and "D06" for V-S Correction Adjustment.
3. Set in order "D05" for V-Linear ity, "D06" for V-S
Correction and set the data to get the best linearity.
4. Then adjust "D02" data until it become a proper
vertical size.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D01".
3. Adjust "D01" data value to center the picture.
Vertical-Phase Adjustment
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D03".
3. Adjust "D03" bus data to get the most acceptable
vertical position.
Note: The step range is 20 (32)+12 (3 steps)/
-20 (5 steps).
(Push once move 4 steps.)
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D04".
3. A black text box will appear on the screen. (see
Figure
C
. below)
4. Adjust "D04" data value to balance the text box
position in the center. (A=B).
Figure C.
A
B
Содержание 26MR70
Страница 11: ...11 6 5 4 3 2 1 A B C D E F G H 26MR70 CHASSIS LAYOUT PWB A PWB B ...
Страница 12: ...12 6 5 4 3 2 1 A B C D E F G H 26MR70 BLOCK DIAGRAM ...
Страница 14: ...15 26MR70 14 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 1 Unit ...
Страница 15: ...17 26MR70 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 2 Unit ...
Страница 16: ...18 6 5 4 3 2 1 A B C D E F G H 26MR70 SCHEMATIC DIAGRAM CRT Unit ...
Страница 17: ...19 6 5 4 3 2 1 A B C D E F G H 26MR70 PRINTED WIRING BOARD ASSEMBLIES PWB B CRT Unit Wiring Side ...
Страница 18: ...20 6 5 4 3 2 1 A B C D E F G H 26MR70 PWB A MAIN Unit Wiring Side ...
Страница 19: ...21 6 5 4 3 2 1 A B C D E F G H 26MR70 PWB A MAIN Unit Chip Parts Side ...