Cleaning the pump impeller
If the accumulation of deposits in the pump, remove the bottom of the pump, as follows:
1. Remove the strainer of the pump casing.
The second stream of clean water and clean impeller by hand crank.
Important: Do not pump impeller!
3. In reverse order to assemble the pump.
Setting the operating point of the ON / OFF
Operating point ON and OFF float switch is adjustable by adjusting the float switch for locking bracket.
Before operating the pump please check the following:
●
The float switch must be installed so that the level of the operating point ON / ON and OFF operating
point level / Off was easily accessible and manageable. So that you can check, put the pump into a
tank filled with water, raise the float switch carefully by hand and then run down again. In this record,
the pump is switched on and off.
●
Ensure that the distance between the head and the float switch bracket blocking too
small.Operation is not guaranteed if the gap is too small.
●
When you set the float switch, make sure the switch before turning touched bottom / foothold.
Attention! Danger of running dry.
SITUATION
CAUSES
MEASURES
The pump does not start
- Is not connected to the
main power supply
- Float switch
- Check the power supply.
- Move the float to a higher
position.
It is not flow
- Inlet sieve is clogged
- Pressure hose is kinked
- Circulation wheel wobbles
- Clean the filter with a water
jet.
- Straighten hose.
- Remove the flange and
clean water stream
The pump does not switch off - The float can not fall down
- Place the pump into the
shaft properly.
insufficient flow
- Inlet sieve is clogged
- Reduced pumping capacity
dirty or abrasive water
- Clean strainer.
- Clean pump and replace
worn parts.
The pump is turned off after a
short operation
-
Thermal protection shuts
down the pump due to
dirty water.
-
Water is too warm.
Thermal fuse shuts off the
pump.
- Turn off the power plug,
clean the pump shaft. Make
sure that the max. Water
temperature of 35
℃
is not
exceeded.
Warranty Note
The guarantee does not apply to:
●
Damage to the mechanical seal "dry" operation or due to foreign objects in the
water.
●
Locking impeller foreign objects.
●
damage during transport.
●
The damage caused by incompetent person.