97-610, 97-6152 • REV. 7/04
13
PRESSURE
W
ASHER
OPERA
T
OR’S MANU
AL
ASSEMBLY INSTRUCTIONS
STEP 1: Attach the high pressure
hose to the spray gun using teflon
tape on hose threads.
STEP 3: Release the coupler col-
lar and push the nozzle until the
collar clicks. Pull the nozzle to
make sure it is seated properly.
STEP 4: Connect the high pressure
hose to the pump discharge fitting.
Push coupler collar forward until se-
cure.
STEP 2: Pull the spring-loaded col-
lar of the wand coupler back to in-
sert your choice of pressure nozzle.
CAUTION: Never replace nozzles
without engaging the safety latch
on the spray gun trigger.
STEP 5: Connect garden hose to the
cold water source.
STEP 6: Check inlet filters, remove
debris, then connect the garden
hose to pump water inlet.
CAUTION: Do not run the pump
without water or pump damage
will result.
Safety
Latch
Spray
Gun
High Pressure
Hose
Wand
Coupler
Pressure
Nozzle
Pressure
Nozzle
Wand
Coupler
Wand
Collar
Cold
Water
Source
Garden
Hose
Water Inlet
Garden
Hose