TROUBLE SHOOTING GUIDE

OPERATING INSTRUCTIONS 

IMPORTANT

:

This unit is equipped 

with a motor protective thermostat.  If for 
some reason the vacuum cleaner should 
overheat, the thermostat will 
automatically turn the unit off.  Should 
this occur:

• Push the On/Off button once.
• Disconnect the plug from the power 

source.

• Check the source of overheating 

problem. (i.e. clogged hose or filter)

Motor Thermostat

• If clogged hose or filter is found, 

unclog the hose and replace the 
filters.

• Wait at least 45 minutes before 

attempting to reuse the vacuum.

• After unit has cooled down for 

45 minutes, plug in the cleaner 
and push the On/Off button. The 
vacuum should start again.

• If the vacuum still does not start, 

contact customer service at 
1 (800) 798-7398.

9

PROBLEM 

POSSIBLE REASON 

POSSIBLE SOLUTION 

VACUUM WILL 
NOT OPERATE 

1. 

Power cord not firmly plugged into 
outlet. 

2. 

No power in wall outlet. 

3. Needs 

servicing. 

4. 

Thermostat has tripped. 

1. 

Plug unit in firmly. 

2. 

Check fuse or breaker. Replace 
fuse/reset breaker. 

3. 

Call 1 (800) 798-7398. 

4. 

Turn the unit off and unplug from 
outlet. Allow unit to cool down, 
then restart. 

VACUUM WILL 
NOT PICK-UP OR 
SUCTION POWER 
IS WEAK 

1. 

Dust cup is full. 

2. Unit 

clogged. 

3. 

HEPA Filter needs cleaning or 
replacing. 

4. 

Debris screen needs cleaning. 

5. 

Filters need cleaning. 

1. 

Empty and clean dust cup. 

2. 

Turn unit off and unplug from 
wall outlet. Remove dust cup 
filter and check for object(s) in 
air duct and remove. 

3. 

Clean or replace HEPA Filter.  

4. 

Clean debris screen. 

5. Clean 

Filters. 

TURBO BRUSH 
DOES NOT 
ROTATE OR 
ROTATES 
SLOWLY 

1. 

Dust cup is full. 

2. 

Rotating brush or elbow is 
obstructed. 

3. Belt 

is 

broken. 

4. Hose 

obstructed. 

5. 

Debris screen is clogged. 

6. 

Filters need cleaning. 

1. 

Empty dust cup. 

2. Clear 

obstructions. 

3. 

Call 1 (800) 798-7398. 

4. Clear 

obstruction. 

5. 

Clean debris screen. 

6. 

Clean ALL filters. 

DUST ESCAPING 
FROM VACUUM 

1. 

Dust cup is full. 

2. 

Dust cup is not installed correctly. 

1. 

Empty and clean dust cup. 

2. 

Review dust cup instructions.  

VACUUM, HOSE 
OR BRUSHES 
WILL NOT PICK-UP 

1. Hose 

clogged. 

2. 

Dust cup is full. 

1. 

Remove hose and/or brushes. 
Remove obstruction from hose 
and /or brush. 

2. 

Empty and clean dust cup. 

Please Note:

The HEPA Filter is washable.  It should, however, be replaced every three (3) 
to six (6) months to ensure peak performance of your vacuum.

The Pre-Motor, Non-Woven Pre-Filter and Post Motor Filters are washable.

Important:

Make sure that 

ALL

filters have been completely air dried for 24 hours before 

re-installing back in the vacuum.

ORDERING REPLACEMENT DUST CUP FILTERS

TO ORDER REPLACEMENT HEPA FILTERS

Item # XSH602

for Model EP602RF

Call:  1 (800) 798-7398

Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time

or

visit our website: www.sharkvac.com

FOR TECHNICAL SUPPORT

for Model EP602RF

Call:  1 (800) 798-7398

Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time

10

Содержание EP602RF

Страница 1: ...OWNER S MANUAL GUIDE DU PROPRI TAIRE Model Mod le EP602RF 120 V 60Hz 10 Amps EURO PRO Operating LLC Boston MA 02465 Tel 1 800 798 7398 www sharkvac com COPYRIGHT EURO PRO OPERATING LLC 2008...

Страница 2: ...pliance over cord 7 Do not operate the system with a damaged cord or plug or if the appliance or any other part of the system has been dropped or damaged To avoid the risk of electric shock do not dis...

Страница 3: ...rs in place 3 OPERATING INSTRUCTIONS WARNING Always remove the power plug from the wall outlet before assembling or removing accessories INSERTING THE TELESCOPIC TUBE INTO THE MAIN UNIT Insert the tel...

Страница 4: ...OPERATING INSTRUCTIONS 6 Turbine Tilt Upwards Locking Latch From time to time the turbine of your turbo brush will require cleaning To do this 1 Remove the turbo brush from the hose or telescopic ext...

Страница 5: ...ll NOT affect the performance of the filter If the HEPA filter is properly TapCleaned after each use and suction does not return to 100 then we suggest that the HEPA filter be TapCleaned vigorously un...

Страница 6: ...cup 2 Turn unit off and unplug from wall outlet Remove dust cup filter and check for object s in air duct and remove 3 Clean or replace HEPA Filter 4 Clean debris screen 5 Clean Filters TURBO BRUSH D...

Страница 7: ...duire le risque d incendie de choc lectrique ou de blessures vitez de laisser branch l aspirateur Lorsque celui ci n est pas utilis ou lorsque vous l entretenez d branchez le cordon d alimentation vi...

Страница 8: ...turbo actionn e l air 22 Remarque Les illustrations peuvent tre diff rentes de votre produit MESURES DE PR CAUTION Important Si l orifice de succion ou le boyau de l aspirateur est BLOQU arr tez l as...

Страница 9: ...ou la brosse pousseter l extr mit du boyau Suceur plat Pour radiateurs fentes coins plinthes et entre les coussins Brosse pousseter La brosse pousseter convient aux meubles stores v nitiens livres aba...

Страница 10: ...Pr Filtre Non tiss Fig 10 Fig 11 4 Tenez le filtre HEPA par ses rebords et tapotez le vigoureusement c t souill vers le bas contre une surface dure et plane jusqu toute la poussi re ait t limin e du...

Страница 11: ...ompl tement pendant 24 heures Ne pas rincer le filtre la laveuse Ne pas le s cher avec un s choir Le laisser s cher l air pendant 24 heures Ne jamais utiliser l aspirateur sans que le filtre post mote...

Страница 12: ...mages ou d fectuosit s caus s par ou d coulant de l envoi des r parations ou des modifications apport s au produit ou ses pi ces et ayant t effectu s par un r parateur non autoris par EURO PRO Operati...