User’s Guide
HRP 220
-
38
-
HS
Fuse
A maintenance engineer should
always
be alerted when a fuse blows. Do not replace the
fuse until the short circuit has been corrected.
14.1
SAFETY MEASURES
Before replacing a fuse always take the following safety measures:
1.
Clear the working surface.
2.
Switch the control units off one by one (switch
L
).
3.
Switch off the main switch (switch
A
).
4.
Remove plug from socket.
5.
Allow the heating elements to cool for at least
10
minutes.
14.2
CONTROL UNIT FUSE
1.
Remove a number of solid core strips at the front of the machine. (Use socket screw
key
no. 5
)
2.
Slide the heating elements backwards.
(see Section
8
).
3.
Slide the cover plate above the defective control unit backwards. (Use socket screw
key
no. 5
)
The fuse is now visible at the back of the control unit.
4.
Open the fuse holder by turning the button loose. The fuse will
come out.
14
10 minutes
4
Fuse holder