User’s Guide
HRP 220
-
35
-
HS
Tensioning and changing filament
13.1
SAFETY MEASURES
Before tensioning and changing the filament always take the following safety measures:
1.
Switch off the foot switch by turning switch
F
to hand operation.
2.
Clear the working surface.
3.
Switch off the control units one at a time (switch
L
).
4.
Turn off the main switch (switch
A
).
5.
Check that the heating elements and pressure bars in the top frame are firmly
attached.
6.
Allow the heating elements to cool for at least
10
minutes.
13.2 TENSIONING
1.
Turn the filament to the lowest position. (Only bottom heating).
2.
Hold the end of the wire on the right with pliers and undo screw
in the wire pin.
(Use socket screw key
no. 2
)
3.
Pull the wire taut with pliers and tension the spring.
4.
Tighten the socket head screw firmly again.
5.
Cut off the end of the filament. Always leave 8-10 mm projecting in order to be able
to tension the filament again.
Bend the projecting piece down.
Attention!
The end of the filament is sharp
.
13
10 minutes
Wire pin
Socket head screw
2
3
4
Содержание HRP 220
Страница 1: ...User s Guide English Plastic bending machine HRP 220...
Страница 42: ...User s Guide HRP 220 41 HS Annex DIAGRAM CONTROL UNIT B...
Страница 43: ...User s Guide HRP 220 42 HS Annex DIAGRAM TIMER UNIT C...
Страница 44: ...User s Guide HRP 220 43 HS Annex MAIN SWITCH UNIT D...
Страница 45: ...User s Guide HRP 220 44 HS Annex DIAGRAM PNEUMATIC SYSTEM E...
Страница 46: ...User s Guide HRP 220 45 HS Annex DIMENSIONS F 1300 2590 1550 1720...