SGS SPG2200 Скачать руководство пользователя страница 1

SPG2200, SPG3000, SPG6500

FOR YOUR SAFETY
PLEASE READ THESE INSTRUCTIONS CAREFULLY
AND RETAIN THEM FOR FUTURE USE.

OWNER’S MANUAL

PETROL GENERATOR

Содержание SPG2200

Страница 1: ...SPG2200 SPG3000 SPG6500 FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL PETROL GENERATOR...

Страница 2: ...NTENTS 3 UNDERSTANDING THE GENERATOR GENERATOR SAFETY 4 EXHAUST GAS PRECAUTIONS 5 EARTHING THE GENERATOR 5 COMPONENTS LOCATION DIAGRAM 6 PREPARING YOUR GENERATOR FIXING THE WHEELS 8 FILLING THE GENERA...

Страница 3: ...earth An earth connector lug is fitted to the generator for use if required to connect to an earth This connection should only be undertaken after full consultation with a competent qualified electric...

Страница 4: ...dle certain models only Fuel tank Air filter box Engine switch Wheels certain models only Pull start 115 V output GENERATOR COMPONENTS LOCATION DIAGRAM Choke selector Spark plug Carburettor adjustment...

Страница 5: ...E GENERATOR WITH OIL 1 Remove the oil reservoir filter cap 2 Fill with 10W30 oil to the centre line of the dipstick 3 Wipe up any oil spillages with a rag 4 Re insert the oil reservoir filler cap Tip...

Страница 6: ...nk window Tip ALWAYS use clean unleaded petrol in the generator NEVER use 2 stroke or other fuels STARTING THE GENERATOR PULL START 1 Disconnect all equipment cables from the 230 V and 115 V outlets 2...

Страница 7: ...t THE GENERATOR SHOULD REQUIRE ONLY ONE OR TWO PULLS TO START Otherise please contact SGS Engineering on 01332 576 850 STARTING THE GENERATOR ELECTRIC START 1 Disconnect all equipment cables from the...

Страница 8: ...outlets As a general rule switch on appliances tools etc that you think will take the most power demand first 3 ALWAYS ENSURE the correct voltage is selected using the voltage selector If the applianc...

Страница 9: ...tlets on the generator 2 Unplug any appliances tools that are plugged into any outlets on the generator 3 Switch the generator to the OFF position 4 Turn the fuel tap so it is pointing LEFT into the o...

Страница 10: ...ote that there is too much oil Check the oil level by using the dipstick and drain excess oil from the oil sump bolt at the bottom of the generator If the pull start mechanism feels too slack i e easy...

Страница 11: ...he filter in clean engine oil and squeeze the filter to remove excess oil Replace the filter into its original posi tion and replace and secure the cover MAINTENANCE INSTRUCTIONS ITEMS REMARKS PRE OP...

Страница 12: ...HAVE ANY NAKED FLAMES DURING THIS PROCESS MAINTENANCE INSTRUCTIONS Draining the fuel You should drain your generator of fuel before you put it into storage Fuel goes stagnant if you left to stand for...

Страница 13: ...PAGE 25 PAGE 24 SPG2200 WIRING DIAGRAM WWW SGS ENGINEERING COM CALL FOR ASSISTANCE 01332 576 850...

Страница 14: ...PAGE 27 PAGE 26 SPG3000 WIRING DIAGRAM WWW SGS ENGINEERING COM CALL FOR ASSISTANCE 01332 576 850...

Страница 15: ...PAGE 29 PAGE 28 SPG6500 WIRING DIAGRAM WWW SGS ENGINEERING COM CALL FOR ASSISTANCE 01332 576 850...

Страница 16: ...erby UK 24th JUNE 2015 SGS Engineering UK Ltd SGS Engineering UK Ltd 2 West Side Park Raynesway Derby DE21 7AZ Petrol Generator SPG2200 SPG3000 SPG6500 2004 108 EC Electromagnetic Compatibility Direct...

Отзывы: