CONVERT UNIT FROM VACUUM USE TO BLOWER USE

1. Remove the elbow tube and vacuum bag by turning the bolts  

 

anticlockwise to loosen the elbow tube.

2. Remove the vacuum tubes by turning the tubes clockwise. 

3. Close the vacuum inlet cover and make sure it is latched closed. 

4. Reinstall the blower tubes (see BLOWER TUBE ASSEMBLY).

1. Pass the shoulder strap over your head and onto your left shoulder. 

2. Extend your right arm toward the rear of the vacuum bag.

3. Adjust shoulder strap until the vacuum bag/shoulder strap seam lies 
between your thumb and index finger. 

4. Make sure air flows freely from the elbow tube into bag. If bag is kinked, 
the unit will not operate properly.

Inspect area before start ing unit. Remove all debris and hard objects such 
as rocks, glass, wire, etc. that can rico chet, be thrown, or otherwise cause 
injury or damage during operation.

This machine produces an electromagnetic field during operation. Under 
some circumstances, this field may interfere with active or passive medi-
cal implants. To re duce the risk of serious or fatal injury, we recom mend 
persons with medical implants to consult their physician and the medical 
implant manufacturer before operating this machine.

SHOULDER STRAP ADJUSTMENT

SAFETY BEFORE USING

1. Stop engine and be sure the impeller blades have stopped turning       
be fore opening the vacuum inlet door.

2. Turn the knob anticlockwise untill the knob is loose. 

3. Pull up the vacuum inlet cover with your hand. Hold the vacuum inlet 
cover open until up per vacuum tube is installed.

           

  

 

       

4. Align the switch on the inside of the vacuum inlet with the slot on the 
upper vauum tube.

5. Push the upper vacuum tube into the vacu um inlet. Turn the tube anti-
clockwise to secure the tube to the blower unit.   

 

6. Align the rib on the lower blower tube with the rib on the upper blower 
tube. Slide the lower vacuum tube on to the upper vacuum tube.

7. When vacuum tubes are fitted together assemble the two tubes 
together with the supplied screws.

ASSEMBLY: VACUUM TUBE

     

 

 

   

WWW.SGS-ENGINEERING.COM

Содержание GPB260

Страница 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL GPB260 LEAF BLOWER VACUUM...

Страница 2: ...um tube is properly installed Avoid the impeller blade with your hand or any foreign object WARNING The blower may throw objects at high velocity that can ricochet and hit the operator WARNING The muf...

Страница 3: ...muffler side facing away from your body and clothes GENERAL SAFETY PRECAUTIONS GENERAL SAFETY PRECAUTIONS Inspect unit before each use for worn loose missing or damaged parts Do not use until unit is...

Страница 4: ...blower outlet clamp bolt upper 6 Secure the elbow tube by turning the bolts clockwise 1 Align the rib on the upper blower tube with the clamp bolt upper in the blower outlet slide the tube into place...

Страница 5: ...during operation Under some circumstances this field may interfere with active or passive medi cal implants To re duce the risk of serious or fatal injury we recom mend persons with medical implants t...

Страница 6: ...ciency deterioration of fuel lines gaskets and internal carbu retor components etc Alcohol blended fuels will cause a high absorption of moisture in the fuel oil mixture causing the separation of oil...

Страница 7: ...jects When starting engine hold the unit as illustrated Do not set unit on any surface except a clean hard area when starting engine or while engine is running Debris such as gravel sand dust grass et...

Страница 8: ...ng Turn idle speed screw clock wise to increase engine speed if engine stalls or dies Turn idle speed screw anticlockwise to de crease engine speed MAINTENANCE CHECK FOR LOOSE FASTENERS AND PARTS Muff...

Страница 9: ...t cannot accidentally cause injury Store unit and fuel well out of the reach of children Remove spark plug and pour 1 teaspoon of 2 stroke engine oil air coded through the spark plug opening Slowly pu...

Страница 10: ...3918 4 Primer button 903919 5 Choke lever 903920 6 Spark plug 903921 7 Throttle trigger 903922 8 Stop switch 903923 9 Upper blower tube 903924 10 Lower blower tube 903925 11 Lower vacuum tube 903926 1...

Страница 11: ...16 Starter Connection plate 904097 1 54 Bolt M5x55 903999 2 17 Bolt M6x12 902350 3 55 Heat Insulation Muffer 904133 1 18 Cylinder cover plate 904099 1 57 Cylinder Gasket 904134 1 19 Bolt ST3 5x10 904...

Страница 12: ...1 108 Bolt ST4 8x16 904066 2 84 Nut M8x1 904042 1 109 Dust Proof Cover 904067 2 85 Washer 8 5x32x2 904043 1 110 Suction pipe 904068 1 86 Impeller 904044 1 111 Suction pipe 904069 1 87 Bearing 61802 90...

Страница 13: ...ecified above conforms to the above European Communities Directive s and Standard s PLACE DATE Signature Robert Wyatt Company Secretary Derby UK 24th NOV 2018 SGS Engineering UK Ltd SGS Engineering UK...

Отзывы: