background image

 

 

In the case of the moving head, which is a 8 channel fixture, you should set the starting address of 
the first unit to 1, the second unit to 9 (8+ 1), the third to 17 (8+ 9) and so on. 
 

 

Control Board 

F

unc

ti

on Mode  

Set Dmx Address 
Value Display 
Set To Slave 
Auto Program 

A001~AXXX 
PAN…… 
Slave1,Slave2,Slave3 
Master / Alone 

DMX address setting 
DMX value display 
Slave setting 
Auto program 

Inf

or

mation  

Time 
Information 

Current Time 
Total Life Hours 
Last Run Hours 
Timer Password 
Clear Last Run 

XXXX(Hours) 
XXXX(Hours) 
XXXX(Hours) 
Password=XXX 
ON/OFF 

Power on running time 
Fixture running time 
Fixture Last times clear 
Timer Password 

038 

Clear Fixture Last time 

Temperature 
Info 

Head Temperature 

XXX

/

℉ 

Temperature in the head 

Software 
Version 

Ver1.0…… 

Software  version  of  each 
IC 

P

ersona

li

ty

 

Status Settings  Address via DMX 

No DMX Status 

ON/OFF 
Close

/

/ Hold /Auto 

Add. via DMX 
Auto run if no DMX 

Display 
Setting 

Shutoff Time 
Key Lock 

02~59m 05m 
ON/OFF 

Display shutoff time 
Key Lock 

Temperature 
C/F 

Celsius 
Fahrenheit 

Temperature 

switch 

between 

/

℉ 

Manual Hold 

ON/OFF 

Keep mannual control 

Reset Default  

ON/OFF 

Restore factory set. 

Ef

fe

ct 

Adjust  

Manual 
Control 

PAN 

PAN =XXX 

Fine  adjustment  of  the 
led 

White Balance 
 

Red…… 

Red =XXX…… 
 

 

White balance adjust 

Edit P

rogr

am

 

Select 
Programs 

Auto  Pro  Part 

Auto  Pro  Part 

Auto  Pro  Part 

Program 1 ~ 10  Program 1 
Program 1 ~ 10  Program 2 
Program 1 ~ 10  Program 3 

Select programs to be run 

Edit Program 

Program 1 

Program 10 

Program Test 
Step 
01=SCxxx 
Step 
64=SCxxx 

(“STEP XX”) 
 

Testing program  
Program in loop 
Save and exit 

Edit Scenes 

Edit 

Scene 

001 
~  Edit  Scene 
250 

Pan,Tilt,…… 
--Secne Time-- 
Input 

By 

Outside 

Pan=xxx…… 
TIME=xx.xs 
 

Save and automatically 
return 
manual scenes edit 

Rec. 

XX~XX 

Automat. scenes rec 

Содержание PALCO 3+

Страница 1: ...GB I D F E P PALCO 3...

Страница 2: ...nection cable 2 One waterproof power cable 3 One safety rope 4 Manual Below are the optional accessories that can be purchased from your local dealer 1 Remote Controller Please carefully check that th...

Страница 3: ...OVERVIEW...

Страница 4: ...User manual of telecontrol BLACK OUT The lamp will be turned off after 1 LED 2 LCD Displ 3 Mode esc 4 Up button 5 Down butt 6 Enter butto 7 IR 8 Power inpu 9 DMX inpu 10 DMX outp...

Страница 5: ...DE button is not pressed If you want to change the address manually you have to press the MODE button then choose one of the fixture that is to be changed A003 etc press SA button to change the addres...

Страница 6: ...and warning notes written in this user manual If the device has been exposed to sudden changes in temperature due to environmental changes do not switch it on immediately The arising condensation mig...

Страница 7: ...permanent operations Consistent operational breaks may ensure that the device will properly function for a long time Do not shake the device Avoid brute force when installing or operating the device...

Страница 8: ...ating the device the first time These installations have to be approved by a skilled technician once a year Cautions The effect should be installed outside areas where people may reach it walking by o...

Страница 9: ...on a flat level surface etc When clamp mounting always use and install the supplied safety cable as an added safety measure to prevent any accidental damage in the event of the clamp failure Make sure...

Страница 10: ...rrect signals control This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of...

Страница 11: ...f each IC Personality Status Settings Address via DMX No DMX Status ON OFF Close Hold Auto Add via DMX Auto run if no DMX Display Setting Shutoff Time Key Lock 02 59m 05m ON OFF Display shutoff time K...

Страница 12: ...nes under Edit scenes With this function you can run the individual scenes either automatically i e with the adjusted Step Time Information Time information Current Time With this function you can dis...

Страница 13: ...ess If you want to set the starting address to 57 set channel 1 to 7 channel 2 to 7 and channel 3 to 57 If you want to set the starting address to 420 set channel 1 to 7 channel 2 to 8 and channel 3 t...

Страница 14: ...nternal programs at 71 4 Set Color_Mode at 255 wait 4 seconds for the target white balance to be stored Edit program Select program With this function you can select the program for the Program Run Ed...

Страница 15: ...rt Select Edit program by turning the encoder Press the Enter button to confirm Select Select programs by turning the encoder Press the Enter button to confirm Turn the encoder to select Auto Pro Part...

Страница 16: ...o Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture INSTRUCTIONS ON USE DMX channel s functions and th...

Страница 17: ...e leds to achieve target white balance 3 Set Internal programs at 71 4 Set Color_Mode at 255 wait for 4 seconds until the target white balance will be stored CLEANING AND MAINTENANCE The following poi...

Страница 18: ...ating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the lamp Please refer...