16
Level 1
Level 2
Level 3
Level 4
Function
SETTINGS
(continued)
Factory Default
-
-
Reset the fixture to factory default settings.
Service Pin
-
-
Contact your SGM dealer or SGM support to request the service pin. Service
use only.
Service Menu
-
-
Only accessible when service pin has been entered. Service use only.
Manual
Quick Color
Red (i-5 / i-5 Red)
0 → 255
Static quick color - red mix (0-255). Set fixture to quick color startup mode.
Green (i-5 / i-5 Green)
0 → 255
Static quick color - green mix (0-255). Set fixture to quick color startup mode.
Blue (i-5 / i-5 Blue)
0 → 255
Static quick color - blue mix (0-255). Set fixture to quick color startup mode.
White (i-5/ i-5 White)
0 → 255
Static quick color - white mix (0-255). Set fixture to quick color startup mode.
Run Program
1, 2 or 3
Run internal sequence 1,2 or 3.
Stop Program
-
Stop current running internal sequence or Quick Color.
Master/Slave
-
Set fixture to operate as Master or Slave fixture.
Editor
Program
1 → 3
Currently selected program (1, 2 or 3).
Scene
1 → 24
Currently selected scene (1-24).
Red (i-5 / i-5 Red)
0 → 255
Red value in currently selected scene (0-255).
Green (i-5 / i-5 Green)
0 → 255
Green value in currently selected scene (0-255).
Blue (i-5 / i-5 Blue)
Blue value in currently selected scene (0-255).
White (i-5 / i-5 White)
White value in currently selected scene (0-255).
Shutter
Shutter setting in currently selected scene (0-255) - according to latest DMX
chart.
Fade Time (Min.)
0 → 999
Fade-in (transition) time to current scene in min. (0-999).
Fade Time (Sec.)
0 → 59
Fade-in (transition) time to current scene in sec. (0-59).
Wait Time (Min.)
0 → 999
Wait (static) time in current scene in min. (0-999).
Wait Time (Sec.)
0 → 59
Wait (static) time in current scene in sec. (0-59).
Test
Off
-
Stops test sequence execution.
Automated Test
-
Initiates a self-test sequence.
Burn-in Test
(30min.)
-
Service use only.
Display Test
-
Service use only.
Control menu - part II