background image

22

Accessories

The i-5 Series can be used with various accessories such as barndoors, color frame, 

and anti-glare shields. 

To get to know all the available i-5 Series accessories, see www.sgmlight.com, or con

-

tact your local SGM dealer.

Accessory holder

The Accessory holder is a mandatory base for holding Barndoors and Color frames to 

the i-5 Series fixture. It is a clip-on accessory that includes a safety wire to be attached 

to the bracket of the fixture, and a knob on the side to allow the sliding of barndoors, 

color frames or rigid diffusion filters.

Barndoors

The i-5 Series have 4-way and 8-way barndoors. The 

difference between the two types is that the 8-way 

barndoors  give  an  extra  control  when  cutting  the 

light, by extending the width of the eight adjustable 

flaps.

The barndoors are designed and intended to be 

mounted on the fixture without the use of any tools. 

It is only required the use of the accessory holder, 

where the barndoors will slide and fit in, by releasing 

the locking knob in the side of the accessory holder. 
The  i-5  Series  barndoors  are  also  compatible  with 

the use of color frame and diffusion filters. 

Floorstand

The i-5 Series have available an optional floorstand, ideal when there is a frequent 

need of changing the position of the fixture between hanging and standing. 
The i-5 floorstand it is easy to mount or remove, simply by the use of 1/4 turn fas

-

teners.

PLEASE NOTE!!

The accessory holder, the barndoors and the floorstand are not intended for permanent outdoor installations.

Anti-glare shields

The i-5 Series feature two different types of optional anti-glare shields:

•  Full anti-glare shield 

- covers the full fixture’s opening 

•  Half anti-glare shield

 - covers half of the fixture’s opening

Using the anti glare shields will remove any unwanted discomfortable glare and reflections.
The anti glare shields are easily mounted by removing the two tilt lock bolts, one in each side of the fixture. Refit the anti glare shield 

in position and screw both tilt locks bolts again. 

Note: This accessory is suitable for both permanent outdoor and indoor installations.

Figure 22: i-5 Series Barndoors

Figure 24: i-5 Series Anti-glare shields

Figure 23: i-5 Series Floorstand

Figure 21: i-5 Series Accessory holder

Содержание I-SERIES

Страница 1: ...USER MANUAL I SERIES I 5 RGBW POI I 5 RED POI I 5 GREEN POI I 5 BLUE POI I 5 WHITE POI I 5 UV POI...

Страница 2: ...es disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained...

Страница 3: ...l device 10 Configuring the device for DMX control 11 Setting a static color manually 12 Using standalone operation 12 Fixture personality settings 13 Fixture properties 14 Control menu part I 15 Cont...

Страница 4: ...height to prevent injury due to falls For Permanent Outdoor Installations POI ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For a t...

Страница 5: ...ixing and adjustable color temperature correction CTC from 2 000K to 10 000K i 5 RGBW only Optional accessories such as barndoors diffusers and anti glare shields Optional internal honeycomb to elimin...

Страница 6: ...acket with fasteners standard only 1 x Omni CRMX Antenna standard only 1 x Spanner with magnet POI only 4 x M 10 screws POI Only Safety information leaflet Location application The standard fixture is...

Страница 7: ...e materials cables or surfaces to be illuminated within 0 3 m 12 in of the fixture 7 Check that there is no risk of the head yoke colliding with other fixtures or structures i 5 Mounting bracket The s...

Страница 8: ...to pages 20 21 for connecting AC power in POI fixtures After connecting the i 5 to power run the on board test by selecting the option TEST AUTOMATED TEST in the menu to ensure that the fixture and e...

Страница 9: ...e or through RDM Please note In POI versions there is no display mounted in the fixture The adjustments are made through RDM See page 19 for more information The OLED display is the human interface of...

Страница 10: ...isn t connected to maintain IP rating Attaching the CRMX wireless receiver POI n a The CRMXTM wireless receiver antenna is an included accessory and is recommended for long range wireless operation Be...

Страница 11: ...ddress sharing can be useful for diagnostic purposes and symmetrical control Set edit DMX address The DMX address is shown on the OLED display in the control panel To change the address setting press...

Страница 12: ...atic color go to MANUAL QUICK COLOR in the menu Note that once the MANUAL QUICK COLOR settings are changed the fixture will be set by default to automatically start in quick color mode whenever it is...

Страница 13: ...t the default fan speed by going to SETTINGS FAN MODE in the menu NOTE In POI version the fan mode adjustment is possible through RDM Setting the LED refresh rate Frequency When using LED lighting wit...

Страница 14: ...Blue White and UV The i 5 RGBW version contains 148 Red 51 Green 48 Blue and 56 White LEDs and can be operated in RGB calibrated mode which ensures that colors are compatible across the range of SGM...

Страница 15: ...ne program Quickcolor Default operating mode Fixture starts up with defined quickcolor Startup Program 1 3 Select program to run at start up program 1 is default Only used if the startup mode is set t...

Страница 16: ...g internal sequence or Quick Color Master Slave Set fixture to operate as Master or Slave fixture Editor Program 1 3 Currently selected program 1 2 or 3 Scene 1 24 Currently selected scene 1 24 Red i...

Страница 17: ...ons allowed Name 0x0080 GET Device Model Description 0x0081 GET Manufacturer Label 0x0082 GET SET Device label 0x0090 SET Factory Defaults 0x1000 GET SET Identify 0x00F0 GET SET DMX Start Address 0x00...

Страница 18: ...pect and enter the correct DMX address or mode DMX cable polarization is inverted pin 2 3 Install a phase inverter to reverse the polarity or replace cables DMX link is not terminated Install a XLR 12...

Страница 19: ...cabled installation and termination When setting addresses through RDM and using USB dongles disable the USB selective suspend to ensure a proper voltage on the DMX link If any lag or trouble occurs w...

Страница 20: ...nstallation and rigging The SGM Omega bracket not included or a customized bracket is needed to install the fixture Consider the dimensions below of the i 5 POI base for customized mounting brackets p...

Страница 21: ...low Ground DMX IN Data DMX IN Data DMX OUT Data DMX OUT Data SGM POI DMX Cable Shield GND White DMX in Data Red DMX in Data Shield GND Black DMX out Data Yellow DMX out Data Junction box DMX cable DMX...

Страница 22: ...he accessory holder The i 5 Series barndoors are also compatible with the use of color frame and diffusion filters Floorstand The i 5 Series have available an optional floorstand ideal when there is a...

Страница 23: ...accessory that must be fitted between the glass front and the optics Although is must be ordered as an accessory the fixture can be customized with the honeycomb at request when ordering Note This acc...

Страница 24: ...l SGM IP rated fixtures made for testing the IP validity after having reassembled the fixture In order to ensure the IP rating of the i 5 Series it s highly recommended that the fixture is always vacu...

Страница 25: ...5 Series can be ordered in any RAL color and with Honey Comb at request Contact your local SGM dealer for ordering customized color housings or for more information i 5 Series accessories Omega brack...

Страница 26: ...2014 35 EU Low Voltage Directive Conforms to 2014 30 EU EMC Directive Conforms to 2011 65 EU RoHS2 Directive Conforms to ANSI UL Std 1573 Certified to CSA Std C22 2 No 166 Approvals and certification...

Страница 27: ...27 User Notes...

Страница 28: ...28 SGM Light A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Отзывы: