14
Connecting AC power
The G-Profile can operate on any 200-240V, 50/60 Hz mains power supply.
Connect the fixture to power using a cable with a Neutrik powerCON TRUE1
connector (supplied with the fixture). Connect both DMX in and DMX out cables
in order to maintain the fixture IP65.
The fixture must be grounded/earthed and be able to be isolated from AC power.
The AC power supply must incorporate a fuse or circuit breaker for fault protec-
tion.
•
Connect the black wire to live
•
Connect the white wire to neutral
•
Connect the green wire to ground (earth)
After connecting the G-Profile to power, run the on-board test, using the
“Test
→
LED Test” menu, to ensure that the fixture is functioning correctly.
See “Control panel menus” on page 22.