Safety information

The R-2 Rail Light is an LED luminaire intended for professional use only. It is not suitable for household use. 

Impropre a l’usage domestique. 

Review the following safety precautions carefully before installing or operating the fixture. This fixture must be installed in ac-
cordance with the applicable installation code by a person familiar with the construction and operation of the fixture and the 
hazards involved. 

Ce produit doit être installé selon le code d’installation pertinent, par une personne qui connaît bien 

le produit et son fonctionnement ainsi que les risques inhérent. 

Preventing electric shock 

Always power off/unplug the fixture before removing any covers. 

Ensure that the power is turned off when connecting the fixture to the AC mains supply. 

Ensure that the fixture is electrically connected to earth (ground). 

Do not apply power if the fixture is in any way damaged. 

Do not immerse the fixture in water or liquid. 

WARNING! 

Read the safety precautions in this section before unpacking, 

installing, powering or operating this product.

WARNING! 

Risk of electric shock.

Manual_R-2_170x113,3.book  Page 6  Thursday, June 4, 2015  9:39 AM

Содержание 80070229

Страница 1: ...R 2 RAIL LIGHT RGBW R 2 RAIL LIGHT WHITE Manual_R 2_170x113 3 book Page 1 Thursday June 4 2015 9 39 AM ...

Страница 2: ...2 Dimensions Measurements in millimetres and inches in brackets Drawing not to scale Manual_R 2_170x113 3 book Page 2 Thursday June 4 2015 9 39 AM ...

Страница 3: ... information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are trademarks owned or licensed by SGM or its affiliates or subsidiaries The original edition of this document is in English All other language editions are translations of the original edition This edition applies t...

Страница 4: ...ion 11 Connecting AC Power 12 Connecting power adaptor to track rail 13 Installing the R 2 Rail Light 14 Pan Tilt adjustment 15 Connecting to a wireless DMX control device 16 Lumen Radio transmitter 17 Local Area Network LAN 18 USB dongle 21 Contents Manual_R 2_170x113 3 book Page 4 Thursday June 4 2015 9 39 AM ...

Страница 5: ...l Light hardware 24 DMX Control 25 Creating a preset RGBW 26 Creating a preset White 26 Service 27 Upgrading the firmware 27 Cleaning 28 DMX protocols 29 R 2 RGBW 29 R 2 White 3000K 4000K 30 Fixtures and accessories 31 Included items 31 Ordering information 31 User s notes 33 Manual_R 2_170x113 3 book Page 5 Thursday June 4 2015 9 39 AM ...

Страница 6: ...ode d installation pertinent par une personne qui connaît bien le produit et son fonctionnement ainsi que les risques inhérent Preventing electric shock Always power off unplug the fixture before removing any covers Ensure that the power is turned off when connecting the fixture to the AC mains supply Ensure that the fixture is electrically connected to earth ground Do not apply power if the fixtu...

Страница 7: ...y in accordance with applicable building codes Do not paint cover or modify the fixture Keep all flammable materials away from the fixture Allow the fixture to cool for 15 minutes after operation before touching it CAUTION Exterior surface temperature after 5 min operation 45 C 113 F Steady state 70 C 158 F WARNING Take measures to prevent burns and fire Manual_R 2_170x113 3 book Page 7 Thursday J...

Страница 8: ... prevent injury due to falls when working at height For permanent installation ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware WARNING Take measure to prevent personal injury Manual_R 2_170x113 3 book Page 8 Thursday June 4 2015 9 39 AM ...

Страница 9: ...y new opportunities to create dynamic and vibrant environments The track adapter system enables retrofitting of your entire setup in the most commonly used tracks available on the market today This can be done in a few easy steps as it is unnecessary to pull new cables etc The R 2 series is available in both black and white housings so that they blend into your existing installations The R 2 RGBW ...

Страница 10: ...ication and terminology A Head B Lens C Base D Lens cap E Control button F Rotational phase selector G Track adapter H Twist lock I Diode E A C G H F B D I Manual_R 2_170x113 3 book Page 10 Thursday June 4 2015 9 39 AM ...

Страница 11: ...maged during transport The R 2 Rail Light is shipped with User manual When selecting a location for the fixture ensure that It is situated away from public thoroughfares and protected from contact with people It has adequate ventilation Manual_R 2_170x113 3 book Page 11 Thursday June 4 2015 9 39 AM ...

Страница 12: ... be able to be isolated from AC power The AC power supply must incorporate a fuse or circuit breaker for fault protection CAUTION Do not open the fixture or connect the fixture to an electrical dimmer system as this can damage it The power cable color coding is given below L2 L3 L1 N Country or Region Phase L Neutral N Protective earth ground European Union EU brown blue green yellow USA Canada bl...

Страница 13: ...rack rail 1 Press the power adaptor into the track rail like shown below 2 Tighten the Phillips screw on the bit of the power adaptor that is visible inside the track rail Manual_R 2_170x113 3 book Page 13 Thursday June 4 2015 9 39 AM ...

Страница 14: ...the fixture into the track rail until it snaps into place 3 Turn the twist locking mechanism to secure the fixture to the track rail 4 Choose the appropriate power circuit by turning the rotational phase selector 1 2 or 3 5 To remove the fixture from the track rail set the rotational phase selector to OFF reverse the twist locking mechanism and pull the fixture out from the track rail 4 3 2 1 Pola...

Страница 15: ...15 Pan Tilt adjustment To adjust pan tilt 330 270 simply rotate the head body of the fixture to the desired position Manual_R 2_170x113 3 book Page 15 Thursday June 4 2015 9 39 AM ...

Страница 16: ...X or DMX RDM and SGM s Rail Light Configuration Tool downloadable from www sgmlight com You can set up the Lumen radio transmitter in the following ways Local Area Network LAN USB dongle SGM USB uploader cable See detailed setup instructions on the following pages Manual_R 2_170x113 3 book Page 16 Thursday June 4 2015 9 39 AM ...

Страница 17: ...17 Lumen Radio transmitter Overview Wireless antenna Link button Link status diode Power status diode Power input 5 pin XLR DMX input Manual_R 2_170x113 3 book Page 17 Thursday June 4 2015 9 39 AM ...

Страница 18: ... Lumen Radio transmitter 1 Connect the Lumen Radio transmitter to power and link it to your PC via an ethernet cable 2 Right click the or depending on your network connection icon and select Open Network and Sharing Center 3 Select Change adapter settings Manual_R 2_170x113 3 book Page 18 Thursday June 4 2015 9 39 AM ...

Страница 19: ...19 4 Select Local Area Connection 5 Select Internet Protocol Version 4 TCP IPv4 and click Properties Manual_R 2_170x113 3 book Page 19 Thursday June 4 2015 9 39 AM ...

Страница 20: ...ess and Subnet mask e g 2 0 0 88 and 255 0 0 0 as shown below and click OK 7 Open the SGM Rail Light Configuration Tool select the appropriate ethernet interface and click OK Manual_R 2_170x113 3 book Page 20 Thursday June 4 2015 9 39 AM ...

Страница 21: ...ireless Lumen Radio transmitter 1 Connect the Lumen Radio transmitter to power and link it to your PC via a USB dongle SGM uploader cable 2 Open the SGM Rail Light Configuration Tool select the appropriate serial interface and click OK Manual_R 2_170x113 3 book Page 21 Thursday June 4 2015 9 39 AM ...

Страница 22: ...nd DMX address to fixture Clear Click to stop fixtures from flashing when assigning DMX addresses Unlink all fixtures from TX Disconnects fixtures from Lumen Radio transmitter DMX address is still assigned Remove preset Click to delete preset from all fixtures Store current preset Click to save current preset For info on how to create a preset see DMX Control on page 25 and 26 Exit Click to exit p...

Страница 23: ...Send all active R 2 Rail Light fixtures will start flashing To assign the chosen DMX address to a specific fixture click the control button on the base of the fixture see parts identification on page 10 for more details The fixture will stop flashing and is now assigned to the chosen DMX address To assign more fixtures to the same DMX address simply click the control button on the desired number o...

Страница 24: ... from an assigned DMX addresses The fixtures will still have the assigned DMX addresses but they will not be active until you click the Link button on the wireless Lumen Radio transmitter Interaction with R 2 Rail Light hardware To physically unlink the R 2 Rail Light fixture 1 Press the control button 2 When the fixture starts flashing press the button again to unlink the fixture To physically st...

Страница 25: ...Up Down or type in value to change offset Adjustment sliders Adjust sliders to control light output and intensity Zero Set all sliders to 0 Full Set all sliders to 255 Manual_R 2_170x113 3 book Page 25 Thursday June 4 2015 9 39 AM ...

Страница 26: ...l button to save the preset The chosen preset value will be saved after power off Creating a preset White Adjust the slider to control intensity When you have achieved the intensity you desire save the preset by 1 Going to Settings in the Configuration Tool and clicking Store current preset or 2 Clicking and holding the control button on the base of the fixture until the fixture s have dimmed up a...

Страница 27: ... download the latest firmware Open SGM s Rail Light Configuration Tool and select Update firmware to upload the latest firmware Select file Click and browse to select file Upload Click to upload file Force upload Click to force upload If you upload software and one or more fixtures fail and you have to try and upload the software again the fixtures that have already adopted the initial software up...

Страница 28: ...ervals within the first few weeks of operation to see whether cleaning is necessary This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult your SGM dealer for a suitable maintenance schedule Clean the R 2 Rail Light using a soft cloth dampened with a solution of water and a mild detergent Do not use products that contain solvents abrasives or...

Страница 29: ... 2 Green 0 255 0 0 100 0 No GREEN Maximum GREEN Fade 3 Blue 0 255 0 0 100 0 No BLUE Maximum BLUE Fade 1 To ensure uniform color between products 3 Channel Mode RGB features full color calibration irrespective of current color setting when you mix 2 or 3 colors Adjusting 1 color does not activate full color calibration Manual_R 2_170x113 3 book Page 29 Thursday June 4 2015 9 39 AM ...

Страница 30: ...K 1 Channel Mode Standard Channel Name DMX value DMX percentage Description Info Default DMX value Fader type 1 White 0 255 0 0 100 0 No Light Maximum Light Fade Manual_R 2_170x113 3 book Page 30 Thursday June 4 2015 9 39 AM ...

Страница 31: ...r no 84010119 R 2 RGBW black housing 35 Order no 84010120 R 2 W 3000K white housing 25 Order no 84010101 R 2 W 3000K black housing 25 Order no 84010102 R 2 W 4000K white housing 25 Order no 84010109 R 2 W 4000K black housing 25 Order no 84010110 Lumen Radio transmitter DMX Order no 80070229 SGM USB uploader cable Order no 83062011 Manual_R 2_170x113 3 book Page 31 Thursday June 4 2015 9 39 AM ...

Страница 32: ...9 1 EN301489 3 EN300328 Conforms to 2006 95 EC Low Voltage Directive EN 60598 1 EN 60598 2 17 EN 62471 Conforms to 2011 65 EU RoHS2 Directive RoHS The information in this document is subject to change without notice Manual_R 2_170x113 3 book Page 32 Thursday June 4 2015 9 39 AM ...