10
3.4 Programming Toggle Option Sections
Some programming sections contain several toggle options. The panel will use zone lights 1 through 8 to indicate if the
different options are enabled or disabled. Press the number corresponding to the option to turn it ON or OFF. Once all
the toggle options have been selected correctly, press the [#] key to exit the section and save the changes. The Ready
light will turn OFF and the Armed light will turn ON.
Refer to the Programming Worksheets in this manual to determine what each option represents and whether the light
should be ON or OFF for your application.
3.5 Viewing Programming
LED Keypads
Any programming section can be viewed from an LED keypad. When a programming section is entered, the keypad will
immediately display the first digit of information programmed in that section.
The keypad displays the information using a binary format, according to the following chart:
Press any of the Emergency Keys (Fire, Auxiliary or Panic) to advance to the next digit. When all the digits in a section
have been viewed, the panel will exit the section; the Ready Light will turn OFF and the Armed light will turn ON, waiting
for the next three-digit programming section number to be entered. Press the [#] key to exit the section.
LCD Keypad
When a programming section is entered, the keypad will immediately display all the information programmed in that
section. Use the arrow keys (< >) to scroll through the data being displayed. Scroll past the end of the data displayed
or press the [#] key to exit the section.
Program Descriptions
The following section explains the operation of all programmable features and options and provides a summary of all
corresponding programming locations.
4.1 Zone Programming Section [001]
The zone definitions describe how each of the zones you use will operate. Program a two-digit code describing the zone
definition in sections [001]. Enter either 00 if the zone is not used or 11 if the zone is used.
Zone Definitions
[00] Null Zone
The zone is vacant. Unused zones should be programmed as Null zones.
[11] 24hr Zone: If the zone is violated, the unit will report to the Central Station, and will log the event to the buffer. This
zone will follow the programmed number of alarms for swinger shutdown.
4.2 Telephone Line Monitor (TLM)
TLM Enable/Disable Section [015]: Toggle option [7]
4.3 Swinger Shutdown
The swinger shutdown feature is designed to prevent a “runaway” communicator from tying up the central station. After
the panel has communicated the programmed number of transmissions for an event, it will no longer report that event
until the swinger shutdown is reset. Different swinger shutdown levels can be set for zone alarms, zone tampers and
maintenance signals.
By default, each Swinger Shutdown limit is set to [003]. The panel will not send more than three signals for each zone
until the swinger shutdown is reset.
Содержание Skyroute UT
Страница 1: ...Installation Manual...
Страница 21: ...20 Skyroute UT Antenna Cable Installation...
Страница 29: ......