9
4.
Spring Washer
Material: Stainless Steel
Size and Length: M8
5.
Nut
Material: Stainless Steel
Size and Length: M8
Bolt torque requirement: tighten the screws
5.2.2 Modules Installed with clamp
Modules should be mounted using specialized clamps as shown in Figure 3.
A)
Modules should be attached on a supporting structure rail by metal clamps. It is recommended to use the
clamps under the following condition or approved by system installation:
Width: Clamp A no less than 50mm Clamp B no less than 38mm;
Thickness: No less than 3mm;
Material: Aluminum Alloy;
Bolt: M8;
B)
Bolt torque requirement: tighten the screws
C)
The Modules clamps must not contact the front glass or deform the frame In any way, the contact area of
damp with the front of frame must be smooth, otherwise maybe damage the frame bring about the modules
broken. Avoid shading effects from the Modules clamps. Drainage holes on the Modules frame must not be
closed or obscured by the clamps.
Figure 3: Clamp Details (Units: mm)