3
1. Aluminum Frame
2. Tempering glass
3. Encapsulating EVA
4. Cell
5. Back sheet
6. Silicone adhesive
7. Junction box
8. Nameplate
9. Cable
10. Connector
11. Mounting hole
12. Grounding hole
13. Drainage hole
14. Cell
3.1 Product Identification
Each module has two labels providing the following information:
1. Nameplate: describes the product type; Peak power, Max. power current, Max. power voltage, open
circuit voltage, short circuit current, all as measured under standard test conditions; Certification marks, the
maximum system voltage etc.
2. Barcode: each individual Module has a unique serial number. The serial number has 16 digits. It is
permanently attached to the interior of the Modules and is visible from the top front of the Module. This
barcode is inserted prior to laminating. In addition, you can find a same barcode beside the nameplate.
3.2 Conventional Safety
Xtremesolar Modules are designed to meet the requirements of IEC 61215 and IEC 61730, application class A.
Modules rated for use in this application class may be used in system operating at greater than 50V DC or
240W, where general contact access is anticipated. Modules qualified for safety through IEC 61730-1 and IEC
61730-2 and within this application class are considered to meet the requirements for safety class II
equipments.
When Modules are mounted on rooftops, the roof must have a fire resistant covering suitable for this
application. Rooftop PV systems should only be installed on rooftop that is capable of handling the
additional weighted load of PV system components, including Modules, by a certified building specialist or
engineer and have a formal structure of the complete analysis result.
For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken
including without limitation fall protection measures, ladders or stairways, and personal protective
equipment.
For your safety, do not install or handle Modules under adverse conditions, including without limitation
strong or gusty winds, and wet or frosted roof surfaces.