44
7 Adjustment menu
7.2
Setting the H
2
S sensor
H
2
S - zero point 0 PPM
release
fresh air
from the
SPE VOL
wait for the display to settle at
a stable value and confirm the
adjustment with the on/off key
(
OK
appears in the LCD)
pressing the
arrow-up key
brings you to the next display
H
2
S - sensitivity 40 PPM
now release test gas
40 PPM
H2S
from the SPE VOL (cf.
section 7.8: Setting the test
gas concentration)
wait for the display to settle at
a stable value and confirm the
adjustment with the on/off key
(
OK
appears in the LCD)
once this has happened, turn
off the test gas feed
pressing the
arrow-up key
brings you to the CO-sensor
setting facility