5
Single-point synchronization
Startup
Product Manual – MOVITRANS
®
TES31A Decentralized Supply Unit Synchronization
46
5.5.6
Compensation
INFORMATION
For more information about compensation, refer to the following documentation:
MOVITRANS® TES31A Decentralized Supply Unit
It is necessary to compensate extremely precisely in single-point synchronization due
to the high transmission power. To ensure that the power transmission is as efficient
as possible, a reduced, standardized compensation range from -0.3 to +0.3 is neces-
sary. This is easily possible with the TCS31A fine compensation.
The following figure shows the compensation range to be observed in single-point
synchronization:
31169746571
The shown standardized compensation range indicates the correct range, regardless
of the synchronization topology. However, it is necessary to interpret the displayed
correction value ΔX differently when setting the TCS31A fine compensation, depen-
ding on the particular synchronization topology.
You can determine the correction value ΔX
TCS
for the TCS31A fine compensation by
dividing the displayed correction value ΔX by the number of synchronized decentral-
ized supply units n
TES
.
∆
∆
X
X
n
TCS
TES
=
31119537163
ΔX
TCS
Correction value for a single TCS compensation box
ΔX
Correction value
n
TES
Number of synchronized TES decentralized supply units
29190657/EN – 04/2020