4
Electrical installation
Assignment of the optional plug connectors at MGF..-DFC and MGF..-DSI
Revision – MOVIGEAR
®
performance
28
4.4.5
X1523: DC 24 V backup voltage, input
The following table shows information about this connection:
Function
DC 24 V backup voltage input
Connection type
M12, 5‑pin, male, L‑coded, color: light gray
Connection diagram
1
4
2
3
Assignment
Contact
Signal
Description
1
+24V/L1
DC 24 V input/L1
(for backup mode)
2
0V24/N2
0V24 reference potential/N2
(for DC 24 V /BES brake rectifier)
3
0V24/N1
0V24 reference potential/N1
(for backup mode)
4
+24V/L2
DC 24 V connection/L2
(for DC 24 V /BES brake rectifier)
FE
Functional earth
26920468/EN – 06/2020