4
Electrical installation
Plug connectors
Revision – MOVIGEAR
®
performance
14
Plug connectors
Not together at a
position with the
plug connector:
Designation
Coding ring/
color
Function
Position
X1203_2
Black
AC 400 V connection
1)
X, 2 or 3
•
X2242
•
X2327
X1206
–
AC 400 V connection (IN)
2)
X, 2 or 3
•
X1203_1
•
X1216
X2242
–
AC 400 V connection (OUT)
2)
X, 2 or 3
•
X1203_2
•
X2327
X2327
Black/green
PA connection for AC 400 V and
DC 24 V backup voltage (OUT)
3)
X, 2 or 3
•
X1203_2
•
X2242
X1216
Black/green
PA connection for AC 400 V and
DC 24 V backup voltage (IN)
3)
X, 2 or 3
•
X1203_1
•
X1206
X5504
Yellow
STO (3-core connection)
4)
X, 2 or 3
•
X2313
X5505
Yellow
STO (3-core connection)
4)
X, 2 or 3
•
X1523
•
X4141
X1523
Light gray
DC 24 V backup voltage - input
5)
X, 2 or 3
•
X5505
•
X4141
X2313
Light gray
DC 24 V backup voltage - output
5)
X, 2 or 3
•
X5504
X4141
Black
Engineering interface
X, 2 or 3
•
X5505
•
X1523
–
–
[1] Optional pressure compensation
1
–
1) Plug connector X1203_1 can also be ordered individually (i.e. without plug connector X1203_2).
2) Plug connector X1206 can be ordered separately (i.e. without plug connector X2242).
3) Plug connector X2327 can also be ordered separately (i.e. without plug connector X1216).
4) Plug connectors X5504 and X5505 can only be ordered together.
5) Plug connector X1523 can also be ordered individually (i.e. without plug connector X2313).
26920468/EN – 06/2020