Startup with EtherNet/IP™
Configuration of the fieldbus stations
Manual – MOVI‑C
®
CONTROLLER standard UHX25A
44
4. Set the correct firmware version of the EtherNet/IP™ scanner.
5. Enter the IP address of the EtherNet/IP™ scanner. You can find the IP address on
the display of the hardware module.
24493782411
ð
In this example, the name of the EtherNet/IP™ scanner is: EtherNetIPScanner.
The IP address of the EtherNet/IP™ scanner is: 192.168.10.39
5.4.4
Integrating and configuring the MOVI‑C
®
CONTROLLER in the fieldbus network
The MOVI‑C
®
CONTROLLER must also be added to the Logix Designer project, con-
nected to the PLC, and configured.
During configuration, the MOVI‑C
®
CONTROLLER is assigned a logical name, an IP
address, and process data with addresses.
Proceed as follows:
ü
You have already downloaded the device description file (EDS file) of the
MOVI‑C
®
CONTROLLER from the SEW‑EURODRIVE website →
www.sew-
eurodrive.com
and saved it locally to the engineering PC (see the chapter "In-
stalling the device description file of the MOVI‑C
ü
You have configured the EtherNet/IP™ scanner in the Logix Designer.
25800736/EN – 08/2018