Startup with EtherNet/IP™
Configuration of the fieldbus stations
Manual – MOVI‑C
®
CONTROLLER standard UHX25A
42
4. Set the version of the device firmware.
24488508683
ð
The project is created. Information about the programs and data in the project is
displayed in the "Controller Organizer" (right-hand screen pane).
5.4.3
Configuring the EtherNet/IP™ scanner
In the "Controller Organizer", the "I/O Configuration" folder contains all the hardware
modules that are responsible for communication with the PLC. An EtherNet/IP™ scan-
ner is used for communicating via Ethernet.
Proceed as follows:
ü
You have created a new Logix Designer project.
1. Right-click to open the context menu of the backplane (1756 Backplane 1756-A7)
and enter a new hardware module.
ð
A catalog with the installed modules is displayed.
25800736/EN – 08/2018