5
10
Gear Units for Trolley Drive Systems - Operating Instructions
Startup of gear units
HW30 and helical-worm gear units HS..
0
0
I
5
Startup
5.1
Startup of gear units HW30 and helical-worm gear units HS..
The direction of rotation of the output shaft on the HS40/41 helical-worm gear
units was changed from CW to CCW in comparison to the predecssor SHB4. Swap
two motor feeder cables to change the direction of rotation.
Running-in
period
The Spiroplan
®
gear unit HW30 and the helical-worm gear unit HS.. require a running-
in period of at least 24 hours before reaching their maximm efficiency. A separate
running-in period for each direction of rotation is required if the gear unit is operated in
both directions of rotation. Table 1 shows the average power reduction during the
running-in period.
Table 1: Power reduction for helical-worm gear units HS.. and Spiroplan
®
gear units HW30
Power reduction for
helical-worm gear unit
HS..
i range
Power reduction
Spiroplan
®
gear unit HW30
i range
1 speed
approx. 12 %
approx.
50...280
approx. 15 %
approx.
40…75
2 speeds
approx. 6 %
approx.
20…75
approx. 10 %
approx.
20…30
3 speeds
-
-
approx. 8 %
approx. 15
4 speeds
-
-
approx. 8 %
approx. 10
5 speeds
approx. 3 %
approx. 6…25
approx. 5 %
approx. 8
Содержание HK40
Страница 2: ...SEW EURODRIVE ...