Gear Units for Trolley Drive Systems - Operating Instructions
11
6
Inspection and maintenance intervals
6
Inspection / Maintenance
6.1
Inspection and maintenance intervals
Table 2: Inspection and maintenance intervals
6.2
Lubricant change intervals
03357AEN
Figure 3: Change intervals for standard gear units under normal environmental conditions.
Change the oil more frequently when using special versions subject to more severe/
aggressive environmental conditions!
Interval
What to do?
→
Section
Every 3000 machine hours
At least every six months
Check the oil
see Section 6.3
Depending on operating conditions
(
→
Figure 3) at least every 3 years
Change mineral oil
Renew the anti-friction bearing
Depending on operating conditions
(
→
Figure 3) at least every 5 years
Change synthetic oil
Renew the anti-friction bearing
Spiroplan
®
gear units HW30 are lubricated for life and, therefore, are maintenance-free.
5000
10000
15000
20000
25000
30000
[h]
CLP PG
CLP HC
CLP
120
[°C]
110
100
90
80
70
0
Oper
at
ing hour
s
Oil bath steady-state temperature
Average value per type of lubricant at 70° C
Содержание HK40