5
Startup
Helical-worm gear units and SPIROPLAN® W gear units
Assembly and Operating Instructions – Explosion-Proof Gear Units
98
5.6
Helical-worm gear units and SPIROPLAN
®
W gear units
Helical-
worm gear
units and
SPIROPLA
N® W gear
units
5.6.1
Run-in period
SPIROPLAN
®
and helical-worm gear units require a run-in period of at least 48 h be-
fore reaching their maximum efficiency. A separate run-in period applies for each dir-
ection of rotation if the gear unit is operated in both directions of rotation. The table
shows the average power reduction during the run-in period.
Helical-worm gear units
Worm
i range
η reduction
1-start
About 50 – 280
Approx. 12%
2-start
About 20 – 75
Approx. 6%
3-start
About 20 – 90
Approx. 3%
4-start
–
–
5-start
About 6 – 25
Approx. 3%
6-start
About 7 – 25
Approx. 2%
SPIROPLAN
®
gear units
W10/W20/W30
W37/W47
i range
η reduction
i range
η reduction
About 35 – 75
Approx. 15%
About 20 – 35
Approx. 10%
About 10 – 20
Approx. 8%
About 30 – 70
Approx. 8%
Approx. 8
Approx. 5%
About 10 – 30
Approx. 5%
Approx. 6
Approx. 3%
About 3 – 10
Approx. 3%
5.6.2
Helical-worm gear unit with projecting worm shaft
WARNING
Risk of explosion due to electric sparks of rotating unit parts.
Fatal and serious injuries.
•
Take appropriate measures to prevent rotating unit parts to come into contact
with foreign objects (e.g. install cover).
CAUTION
Risk of injury due to rotating parts.
Injuries
•
Before you operate the helical-worm gear unit using the inserted handwheel or
the hand crank, de-energize the drive.
•
If the handwheel or the hand crank remains attached to the shaft during opera-
tion, take appropriate measures to prevent injuries.