8
Technical data
Encoders
Operating Instructions – AC Motors
220
8.8.7
EV2.
Encoder
EV2T
EV2S
EV2R
EV2C
For motors
DR..71 – DR..225
DRN71 – 225
DR2..71 – 80
Supply voltage
U
B
DC 5 V
DC 9 V – 26 V
Max. current consumption
I
in
160 mA
RMS
120 mA
RMS
160 mA
RMS
250 mA
RMS
Max. pulse frequency
f
max
120 kHz
Incremental tracks, periods per re-
volution
A, B
1024 (10 bits)
Position resolution, increments
per revolution
A, B
4096 (12 bits)
Incremental tracks, periods per re-
volution
C
1
Output amplitude per track
V
high
≥ 2.5 V
1 V
PP
≥ 2.5 V
≥ V
B
- 3.5 V
V
low
≤ 0.5 V
≤ 0.5 V
≤ 3 V
Signal output
TTL
sin/cos
TTL
HTL
Output current per track
I
out
25 mA
RMS
10 mA
RMS
25 mA
RMS
60 mA
RMS
Pulse duty factor
1 : 1 ± 20%
sin/cos
1 : 1 ± 20%
Phase angle A: B
90 ° ± 20 °
90 °
90 ° ± 20 °
Data memory
–
Vibration resistance
≤ 100 m/s²
Shock resistance
≤ 1000 m/s
2
≤ 3000 m/s
2
≤ 1000 m/s
2
Maximum speed
n
max
6000 min
-1
Mass
m
0.36 kg
Degree of protection
IP66
Port
Terminal box on incremental encoder