7
Inspection/maintenance
Inspection/maintenance work diagnostic unit /DUB
Operating Instructions – AC Motors
177
7.7.4
Inspection/maintenance of the diagnostic unit /DUB with microswitch for wear monitoring
1. Check the working air gap according to chapter "Setting the working air gap of
160) and adjust it if necessary.
2. Screw the hex head screw [560] against the actuator of the microswitch [555] until
it trips (brown, blue contacts closed).
While screwing, install hex nut [561] to eliminate the longitudinal play from the
thread.
3. Screw the hex head screw [560] further in from the actuated switching point, so
that the microswitch [555] remains activated (contact brown-blue closed). Depend-
ing on the brake size, screw the hex head screw [560] further in by the specified
angle to set the wear point:
Brake
Standard brake
without safety encoder
With safety brake or
safety encoder
BE2
135°
135°
BE5
270°
180°
BE11, BE20, BE30,
BE32, BE60, BE62
360°
BE120
270°
135°
BE122
180°
90°
•
After reaching the respective end position, tighten the hex nut [561] against the
bolts [557]/[945] while holding the hex head screw [560] to keep it in the correct
position.
•
Check if the cables are routed firmly and if they require additional fastening in form
of cable ties [1109]. Make sure the cables are routed in a sufficient distance to the
fan wheel of the motor.
•
Install the previously removed motor parts again.
25851535/EN – 02/2019
Содержание DR 315 Series