Manual – XFE24A EtherCAT Fieldbus Interface
57
8
Configuration of the SEW communication server
Operating MOVITOOLS® MotionStudio via EtherCAT
3. The "Configure EtherCAT" window opens. Click on the "+" button [1] to add the IP
address of the mailbox gateway in the EtherCAT master.
4. In the [Settings] / [Options] menu, call up the "Online mode" menu item. Ensure that
the "Never execute automatically" [1] option is ticked in the "Cyclic accessibility" field.
61937AXX
[1]
For the basic settings, observe the specified unit scan range ("Scan range start / end"
fields). EtherCAT addresses 1001 to 1010 are scanned as standard. For large Ether-
CAT networks, you must adjust this unit scan range accordingly.
61938AXX
[1]