Manual – XFE24A EtherCAT Fieldbus Interface
8
Configuration of the mailbox gateway
Operating MOVITOOLS® MotionStudio via EtherCAT
8.5
Configuration of the mailbox gateway
• Activate the VoE / EoE support of the EtherCAT controller.
• Determine the IP address of the EtherCAT mailbox gateway. Usually the IP address
is assigned by the TwinCAT program. It should not be changed.
In the TwinCAT program of Beckhoff, the above settings look as follows:
8.6
Network settings on the engineering PC
If MOVITOOLS
®
MotionStudio runs on the EtherCAT master, no network settings need
to be made.
If the EtherCAT master is connected to an Ethernet network, PCs in the same subnet
can use MOVITOOLS
®
MotionStudio for accessing SEW drives on the EtherCAT
(
→
sec. "8.2"). For this purpose, the telegrams from the engineering PC are forwarded
via the Ethernet interface of the EtherCAT master to the mailbox gateway (so-called
routing).
11649AXX
Figure 26: Setting the IP address for the EtherCAT mailbox gateway
0
0
I