Doc. # 177/52701
Rev3
7-4
You can access the FIFO using objects 41X1
h
and 41X2
h
. The FIFO index is entered at 41X1
h
and the data is read from 41X2
h
.
Event counters
The controller provides 10 event counters at 4200
h
to 420A
h
. Each event counter can record
information about occurrences of one event. The allocation of event counters to events is user-
configurable however Gen4 will automatically count important events in unused counters. The
information recorded in each event counter is:
The time of the first occurrence
The time of the most recent occurrence
The number of occurrences
Operational monitoring
At objects 4300
h
and 4301
h
, Gen4 monitors and records the minimum and maximum values of
these quantities:
Battery voltage
Capacitor voltage
Motor current
Motor speed
Controller temperature
Two instances of the operational monitoring log are maintained. Service engineers can access
and clear the first log; the second is accessible and clearable only by Sevcon engineers. The
Customer copy is normally recorded and reset each time the vehicle is serviced. The Sevcon
copy records data over the controller’s entire working life.
CANopen abort code
The controller will sometimes respond with a CANopen General Abort Error (08000000
h
) when
the object dictionary is accessed. This can occur for many reasons. Object 5310
h
gives the exact
abort reason. These are:
0
None
12 Invalid value
24 Cannot read from DSP
1
General
13 EEPROM write failed
25 Peek time out
2
Nothing to transmit
14 Unable to reset service
time
26 Reserved for future use
3
Invalid service
15 Cannot reset log
27 Reserved for future use
4
Not in pre-operational
16 Cannot read log
28 Reserved for future use
5
Not in operational
17 Invalid store command
29 Reserved for future use
6
Cannot go to
pre-operational
18 Bootloader failure
30 Reserved for future use
7
Cannot go to
operational
19 DSP update failed
31 Reserved for future use
Содержание Gen4
Страница 1: ...Gen4 Applications Reference Manual Document no 177 52701 Rev 3 3 ...
Страница 9: ...Chapter 1 Introduction ...
Страница 13: ...Chapter 2 About the Gen4 ...
Страница 25: ...Chapter 3 Installation ...
Страница 45: ...Chapter 4 Specification ...
Страница 47: ...Specification Doc 177 52701 Rev 3 3 4 3 CAUTION Repetitive short circuits may damage the controller ...
Страница 50: ...4 6 Isolation Any terminal to the case Meets EN1175 1 1998 and ISO3691 Complies with IEC 60664 ...
Страница 53: ...Specification Doc 177 52701 Rev 3 3 4 9 Dimensions Size 2 models Size 4 models ...
Страница 54: ...4 10 Size 6 models ...
Страница 55: ...Chapter 5 System design ...
Страница 60: ...5 6 Single traction wiring diagram Figure 13 Single traction wiring diagram ...
Страница 61: ...System design Doc 177 52701 Rev 3 3 5 7 Single pump wiring diagram Figure 14 Stand alone pump wiring diagram ...
Страница 63: ...System design Doc 177 52701 Rev 3 3 5 9 On board fuse See On board fuse mounting on page 3 11 ...
Страница 64: ...5 10 Figure 15 Dual traction wiring diagram ...
Страница 70: ......
Страница 71: ...Chapter 6 Configuration ...
Страница 110: ......
Страница 111: ...Chapter 7 Monitoring Gen4 ...
Страница 122: ......
Страница 123: ...Monitoring Doc 177 52701 Rev 3 3 A 1 ...