SES SE-2020 Скачать руководство пользователя страница 3

 

 
 

SEALED ENERGY SYSTEMS

®

 

User Manual  

      

1.

 

REVISION HISTORY 

 

2.

 

INTRODUCTION 

2.1 

Scope 

 

This  specification  describes  the  physical,  functional  and  electrical 
characteristics  of  a  rechargeable  Lithium  Ion  battery  SE-2020  by 
Sealed  Energy  Systems  (SES®).  This  specification  is  the  interface 
document  between  SES®  and  its  customers.  It  is  understood  that 
the customer may create their own internal specification. However, 
this specification is the master that defines the battery’s operation.  

 

2.2 

Battery Pack Overview 

 

This  specification  describes  the  physical,  functional  and  electrical 
requirements  for  the  SE20200NR29  Smart  Battery  including  a 
rechargeable  Lithium  Ion  battery  and  a  Battery  Management 
Module. The battery consists of nine (09) Lithium Ion rechargeable 
cells of  INR-18650 size, assembled  in a  3  series /  3  parallel (3S3P) 
configuration. Each cell has an average voltage of 3.6V and a typical 
capacity of 2.85Ah giving a battery pack of 10.8V & 8.55Ah typical. 
The  battery  is capable of  communicating with host or  the charger 
through the System Management Bus (SMBus). The battery is fully 
SMBus and SBDS Revision 1.1compliant. Protection is provided for 
over-charge,  over-discharge  and  short  circuit.  For  redundancy, 
passive safety devices have been integrated into the pack to protect 
against  over-  current  and  over-temperature,  and  secondary 
overvoltage has been implemented with a logic-fuse and controller. 

Revision 

Release 
Date 

Revisions 

Issued 

Approved 

1.0 

20/10/2019  Released 

SES 

MGM 

1.1 

26/12/2019 

Certificate of 
Compliance issued on 
UN38.3 and IEC/      
EN 62281 

NEMKO 

MGM 

1.2 

08/01/2020 

Certificate of 
compliance, EU REACH 
Regulation no. 
1907/2006 article 
33(1) contents of all 
SCHV <0.1% w/w 

INTERTEK 

MGM 

1.3 

08/01/2020 

Certificate of 
compliance, REACH 
Ann-II of 2011/ 65/EU 
and adm EU 2015/863 

INTERTEK 

MGM 

1.4 

29/01/2020 

BIS, Certificate of 
Registration issue on 
IS 16046-2: 2018  

INTERTEK 

MGM 

1.5 

19/02/2020 

Certificate of 
Compliance issued on 
IEC/EN 62133-2: 2017 

NEMKO 

MGM 

Содержание SE-2020

Страница 1: ...ery Model SE 2020 SE20200NR29 10 8V 8 55AH 92 34Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...pical capacity of 2 85Ah giving a battery pack of 10 8V 8 55Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMB...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Страница 7: ...80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notifi...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...eparate pull ups to system logic voltage NOT the battery voltage Typically a 15K pull up resistor is used but please refer to the SMBus Specification for additional info 3 2 Fuel Gauge Electronics 3 2...

Страница 10: ...MBus level II or level III charger The system has three modes of operation normal sleep and shutdown In normal mode measurements calculations protection decisions and data updates are made on 1 sec in...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...p condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a co...

Страница 14: ...3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus slave using th...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2020 Device Chemistry 0x22 Returns a...

Страница 18: ...hreshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Disc...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Current...

Страница 21: ...ection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specifications 3 7 1 EMC and Saf...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: