3.3.10. Pack Calibration cycle  

 

The  fuel-gauge  uses  the  Impedance  Track  Technology  to  measure 
and  calculate  the  available  charge  in  battery  cells.  The  achievable 
accuracy is better than 1% error over the lifetime of the battery. Max 
Error  increases  by  1%  in  20  cycles,  e.g.,  only  occasionally  is  a  full 
charge/discharge learning cycle required to maintain high accuracy. 
 
 

3.4. 

Protection Electronics    

 
 

3.4.1.  Overview of Operations 

 
Electronic circuitry is permanently connected within the battery pack 
to  prevent  damage  if  either  the  charger  or  host  device  fails  to 
function correctly. The circuitry also protects the battery if an illegal 
current  source  is  placed  across  the  battery  terminals,  or  an  illegal 
load  is  connected.  Redundant  levels  of  protection  have  been 
implemented (the primary protection levels are auto-resettable and 
the secondary are non-resettable). 
 
 
 

3.4.2.  Charge Protection  

 
Over-Voltage: 

 

The primary protection circuit will prevent the battery from 
charging if any cell voltage >= 4300mV. Then, once all cell 
voltages are <= 4150mV, it will allow charging again. 

 

The secondary protection circuit will prevent the battery from 
charging if any cell voltage >= 4.35V +/-0.05V by blowing a 
power path logic fuse. The fuse is non-re-settable rendering 
the battery pack non-functional. 

Over-temp: 

 

The  primary  protection  circuit  also  provides  over-
temperature  protection  and  will  prevent  the  battery  from 
charging  at  temperatures  =>54ºC  (see  paragraph  3.1.5  for 
Charge  Current()  request).  Then,  once  the  battery 
temperature  has  cooled  to  <=45ºC,  it  will  again  allow 
charging. 

Over-Current: 

 

The primary protection circuit also provides continuous over-
current protection and will prevent the battery from charging 
at Current() =>4.35A*. Then, once the Average Current() <= 
200mA for 70sec, the battery will re-test the over-current 
condition, and again allow charging. 
*Note: Current values vary time to time. Check SDS with SES® 

Содержание SE-2020

Страница 1: ...ery Model SE 2020 SE20200NR29 10 8V 8 55AH 92 34Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...pical capacity of 2 85Ah giving a battery pack of 10 8V 8 55Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMB...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Страница 7: ...80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notifi...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...eparate pull ups to system logic voltage NOT the battery voltage Typically a 15K pull up resistor is used but please refer to the SMBus Specification for additional info 3 2 Fuel Gauge Electronics 3 2...

Страница 10: ...MBus level II or level III charger The system has three modes of operation normal sleep and shutdown In normal mode measurements calculations protection decisions and data updates are made on 1 sec in...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...p condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a co...

Страница 14: ...3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus slave using th...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2020 Device Chemistry 0x22 Returns a...

Страница 18: ...hreshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Disc...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Current...

Страница 21: ...ection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specifications 3 7 1 EMC and Saf...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: