Host-to-Battery Messages (cont.) 

  Function 

Command 

Code 

 Description 

 Unit  Access 

Default 
(POR) 

Charging Voltage() 

0x15 

Returns the battery’s desired charging 
voltage. 

mV 

12600 

Battery Status() 

0x16 

Returns the battery’s status word. 

Bit flags 

0x2C0 

Cycle Count() 

0x17 

Returns the number of charge/discharge 
cycles the battery has experienced. A 
charge/discharge cycle is defined as: an 
amount of discharge approximately 
equal to the value of Design Capacity. 

cycles 

Design Capacity() 

0x18 

Returns the theoretical capacity of the 
new battery. 

mAh 

8700 

Design Voltage() 

0x19 

Returns the theoretical voltage of a new 
battery. 

mV 

10800 

Specification Info() 

0x1a 

Returns the version number of the SBDS 
the battery pack supports, as well as 
voltage and current scaling information. 

word 

0x0031 

Manufacturer 
Date() 

0x1b 

Returns the date the electronics were 
manufactured. 

word 

 

Serial Number() 

0x1c 

Returns the electronics serial number.  number 

 

Manufacturer 
Name() 

0x20 

Returns a character array containing the 
manufacture’s name. 

string 

SES 

Device Name() 

0x21 

Returns a character array that contains 
the battery’s name. 

string 

SE-2020 

Device Chemistry() 

0x22 

Returns a character array that contains 
the battery’s chemistry. 

string 

LION 

Manufacturer 
Data() 

0x23 

Returns data specific to the 
manufacture. 

 

 

3.3.8.  Battery to charger Messages (Master Mode)

 

 

The battery, acting in the role of a bus master, uses the write word 
protocol to communicate with the charger, operating in slave mode. 
If the CHARGER_MODE bit in Battery Mode() is clear, the Battery will 
broadcast Charger request information every 10 to 60 second. 

 

Battery-to-Charger Messages 

Function 

Command 

Code 

Description 

Unit  Access 

Charging 
Current() 

0x14 

Sends the desired charging rate to the 
battery charger 

mA 

Charging 
Voltage() 

0x15 

Sends the desired charging voltage to the 
battery charger 

mV 

 
 
 

3.3.9.  Critical Messages (Master Mode) 

 
Whenever the Battery detects a critical condition, it takes the role of 
a bus master and sends Alarm Warning() message to the Host and/ 
or Charger. The Battery broadcasts the Alarm Warning() message at 
10 second intervals until the critical condition(s) has been corrected. 
 

 

Содержание SE-2020

Страница 1: ...ery Model SE 2020 SE20200NR29 10 8V 8 55AH 92 34Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...pical capacity of 2 85Ah giving a battery pack of 10 8V 8 55Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMB...

Страница 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Страница 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Страница 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Страница 7: ...80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notifi...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...eparate pull ups to system logic voltage NOT the battery voltage Typically a 15K pull up resistor is used but please refer to the SMBus Specification for additional info 3 2 Fuel Gauge Electronics 3 2...

Страница 10: ...MBus level II or level III charger The system has three modes of operation normal sleep and shutdown In normal mode measurements calculations protection decisions and data updates are made on 1 sec in...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...p condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a co...

Страница 14: ...3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus slave using th...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2020 Device Chemistry 0x22 Returns a...

Страница 18: ...hreshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Disc...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Current...

Страница 21: ...ection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specifications 3 7 1 EMC and Saf...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: