Dimmer 74-350

Operation

This 750VA universal dimmer is designed for DIN-rail mounting 
and is 2U wide. This universal dimmer is suitable for dimming 
resistive, inductive and capacitive loads. The total connected 
load can max. amount to 750VA. The dimmer functions both as a 
phase control dimmer and as a reversed phase control dimmer. 
The choice between both dimming principles is automatically 
made. The dimmer can be used with or without memory and is 
provided with an automatic detection and indication of overload. 
The following 4 operating modes are possible: 0-10V analog 
control; 1-10V analog control; 1 push button operation and 2 
push button operation.

Installation

The load (min. 60VA; max. 750VA) has to be connected to the 
'load connection terminals' (see 

Fig. 1

), between terminal N and 

terminal 

.

Connect the control to the ‘control terminals’ (see 

Fig. 1

). 

The power supply is connected to the ‘connection terminal 
power supply 230V~’, between terminals L and N (see 

Fig. 1

). 

The following 4 operating modes are possible (

Fig. 2 and 3

): 

-  analog 0-10V control, to be connected to terminals 1 and 3
-  analog 1-10V control, to be connected to terminals 1 and 3
-  1-button control mode with push buttons, to be connected to 

terminals 1 and 3 + possibility to connect atmosphere button 
between terminals 1 and 2. 

-  2-button mode with push buttons, to be connected to 

terminals 1, 2 and 3

If everything has been connected correctly and the power is 
switched on, the load LED and the error indication LED light 
simultaneously for 1s. If no load is connected, both LEDs blink.
A connected load can manually be switched on and off by 
means of the select button.

Installation recommendations:
-  If you install several modules next to each other, maintain a 

distance of min. 1 module with suitable blank plates.

-  When installing several dimmers on top of, or alongside each other, 

it may be necessary to reduce the max. power (see load table).

-  Preferably place the dimmers at the bottom of the distribution 

board.

-  Check the temperature. If the temperature in the distribution 

board rises too high (max. 35°C), provide additional ventilation. 

-  This appliance is not suitable for controlling motors.
-  When using a ferromagnetic transformer, check whether it is 

suitable for use in combination with an electronic control.

-  When using halogen lighting with ferromagnetic transformers, 

take into account the effi ciency of the transformers. Load the 
transformers to at least 80% of their nominal power. Take into 
account the effi ciency of the transformer when calculating the 
total dimmer load. The transformer has to be suitable for dimming.

-  Electronic transformers can exhibit unstable behaviour if the 

wire length between the transformer and the lamps exceeds 2m.

-  Lamps that are connected through dimmers do not light at the 

max. light intensity. There light level will always be smaller than the 
light level of an identical lamp connected directly to the mains. 

-  Do not switch on the dimmer if the transformers are not loaded.

Settings

Factory setting

The dimmer is running in mode 1: 0-10V analog

A. Select operating mode

You can modify the operating mode. Enter the dimmer’s 
programming mode: press the select button for >3s.
-  the load switches off
-  the input LED 0-10V  blinks.

> 3s

To modify the operating mode, briefl y press the select button repeatedly. 
The operating mode is indicated by a blinking input LED. 
Note: if you select 2-button mode, all LEDs blink.

In programming mode, the input LEDs can have the following meaning:

LEDs 

 

      Meaning

Upper LED blinks, the other 
LEDs are out.

Selection of 0-10V 
control (mode 1)

Middle LED blinks, the other 
LEDs are out.

Selection of 1-10V 
control (mode 2)

Lower LED blinks, the other 
LEDs are out.

Selection of 1-button 
mode (mode 3)

All LEDs blink.

Selection of 2-button 
mode (mode 4)

Exit the dimmer’s programming mode to save the selected 
operating mode: press the select button >3s:
-  the input LEDs no longer blink, only the input LED of the 

selecte doperating mode blinks continuously (if the 2-button 
mode was selected, all input LEDs are out).

Note: if not action is carried out in programming mode for 3min, 
the programming mode is automatically exited. The settings are 
not saved. 

Содержание 74-350

Страница 1: ...Dette apparat er ikke egnet til at styre motorer Hvis der anvendes en jernkernetransformator skal man sikre sig at denne er egnet til anvendelse sammen med elektronisk styring Hvis der anvendes halogenbelysning sammen med jernkerne transformatorer skal der tages højde for transformatorernes ydeevne Transformatorerne skal belastes med mindst 80 af deres nominelle effekt Tag højde for transformatore...

Страница 2: ...e går ikke tabt i tilfælde af strømsvigt Når hukommelsesfunktionen er slået til vil lysdæmperen først tændes ved min lysintensitet Derefter vil lysdæmperen skifte til den lysværdi som sidst blev indstillet Med hukommelse Kort tryk Tænd Sluk Tænd ved forrige niveau Langt tryk dæmp op ned Langt tryk mens lysdæmperen er slukket lysdæmperen regulere op fra min Når der reguleres op lysdæmperen stopper ...

Страница 3: ...pænding eller overstrøm kortslutning belastningen kan ikke dæmpes hverken i forkants eller i bagkantsstyring Drift vedligeholdelse Ingen vedligeholdelse Ved fejl eller driftforstyrrelser skal en autoriseret el installatør kontaktes Tekniske data Input Forsyning 230 V 10 50 Hz Maks spændingsfald over lysdæmper 5 Egetforbrug 1 W Indgangsimpedans 0 10 V 33 k 1 10 V 22 k Udgang Mindste belastning 60 W...

Страница 4: ... électriques doivent exclusivement être exécutés par un électricien agréé En cas de défaut ou de perturbation du fonctionnement contacter un installateur électricien agréé Sous réserve de modifications 1 2 3 1 Lastanschlussklemmen N 2 Anschlussklemmen Netz 230 V L N 3 Last LED 4 Fehleranzeige LED 5 Input LED s Mode 6 Auswahl Taste Mode 7 Anschlussklemmen Ansteuerung 1 bis 3 1 Belastningstilslutnin...

Страница 5: ...ble Preferably place the dimmers at the bottom of the distribution board Check the temperature If the temperature in the distribution board rises too high max 35 C provide additional ventilation This appliance is not suitable for controlling motors When using a ferromagnetic transformer check whether it is suitable for use in combination with an electronic control When using halogen lighting with ...

Страница 6: ...With memory function the dimmer first switches on at min light intensity Then the dimmer switches on at the last set light value With memory Press briefly switching on off on at previous level Press long dimming up dimming down Press long when dimmer is off dimmer dims up from min When dimming up dimmer stops at max value When dimming down dimmer stops 2s at min value and then dims up A renewed lo...

Страница 7: ...voltage or overcurrent short circuit the load is not dimmable neither in phase control nor in reverse phase control Operation maintenance No maintenance Contact a qualified electrician in the event of fault or breakdown Technical data Input Power supply 230 V 10 50 Hz Maximum voltage drop over dimmer 5 Own consumption 1W Input impedance 0 10V 33k 1 10V 22k Output Minimum load 60W Maximum load 750V...

Страница 8: ...weise Falls mehrere Dimmer direkt nebeneinander installiert werden beachten Sie einen min Abstand von 1 Modul mittels angepassten Blindplatten Falls mehrere Dimmer übereinander oder direkt nebeneinander installiert werden kann es erforderlich sein die max Belastung einzuschränken siehe Belastungstabelle Montieren Sie die Dimmer vorzugsweise unten in den Verteiler kasten Kontrollieren Sie die Tempe...

Страница 9: ...gang 2 unterschiedliche und unabhängige Funktionen Eingang 1 hat eine 1 Tasterdimmfunktion einstellbar mit oder ohne Lichtwertspeicher Mit Eingang 2 ist es möglich Lichtszenen abzuspeichern und jederzeit wieder aufzurufen Funktionsweise Eingang 1 Anschlussklemmen 1 und 3 Eingang 1 hat eine 1 Tasterdimmfunktion Siehe Fig 3 Lichtwertspeicherfunktion Der Dimmer kann sowohl mit als auch ohne Lichtwert...

Страница 10: ... blinkt Input LED s Fig 1 Es können verschiedene Ansteuerungsmethoden gewählt werden z B 0 10V Analogsteuerung 1 10V Analogsteuerung 1 Tasterbedienung oder 2 Tasterbedienung Die Input LED s zeigen an welche Ansteuerungsmethode gewählt ist Im normalen Betrieb können die Input LED s folgendes anzeigen LED s Bedeutung Obere LED leuchtet ständig Aktuelle Ansteuerungsmethode 0 10V Mittele LED leuchtet ...

Страница 11: ...Verdrahtungslänge bis zum letzten Taster 100m Verdrahtung der Analogsteuerung Steuerstromkreis und Leistungsteil des Dimmers sind galvanisch getrennt Die Ansteuereingänge des Dimmers entsprechen den Anforderungen für Schutzkleinspannung SELV Falls die Steuer signale ebenfalls aus SELV Geräten kommen werden keine speziellen Drahtquerschnittsanforde rungen oder Isolations anforderungen an die Steuer...

Страница 12: ...laissant des plaques vides Si vous installez plusieurs variateurs l un au dessus de l autre ou l un à côté de l autre il peut s avérer nécessaire de réduire la puissance maximale voir le tableau de charge Il est préférable de positionner les variateurs en bas du tableau de distribution Vérifier la température Si la température dans le tableau de distribution monte trop max 35 C assurer une ventila...

Страница 13: ...mémoire L entrée 2 permet de sauvegarder et d extraire les ambiances lumineuses à tout moment Fonctionnement de l entrée 1 bornes 1 et 3 L entrée 1 a un mode de fonctionnement 1 bouton Voir Fig 3 Fonction mémoire Le variateur peut être utilisé avec ou sans mémoire Le variateur est réglé sur le mode 1 bouton avec fonction mémoire en standard Pour paramétrer le variateur sans fonction mémoire il suf...

Страница 14: ... bouton ou 2 boutons Les LED d entrée indiquent le mode de fonctionnement sélectionné En cas de fonctionnement normal les LED d entrée peuvent avoir les significations suivantes LED Signification La LED supérieure s allume en continu Mode en cours 0 à 10 V La LED intermédiaire s allume en continu Mode en cours 1 à 10 V La LED inférieure s allume en continu Mode en cours mode 1 bouton Aucune des tr...

Страница 15: ...circuit électrique du variateur ont une isolation galvanisée Les entrées de commande du variateur sont conformes aux exigences applicables aux tensions extra faibles de sécurité SELV Si les signaux de commande viennent d appareils électriques respectant eux aussi les exigences SELV aucune exigence particulière n est applicable en ce qui concerne le diamètre des câbles ou l isolation des câbles de ...

Отзывы: