174
Part Number STH14 5/09
S/SV150 6 Valve Diagram
S/SV175 8 Valve Diagram
3
INTERNAL CARBONATOR TANK
PLUMBING: 2-1-1-2 MANIFOLDING
*OPTIONAL*
VARIETY VALVE ON #3
1 – WATER
(THRU COLDPLATE)
2 – SYRUP
(AMBIENT)
3 – SYRUP
(AMBIENT)
4 – SYRUP
(THRU COLDPLATE)
VALVES “SYRUP LINES NOT SHOWN”
P
R
E
-CHILL OUT
T
O
CA
RB
ONA
T
O
R
6
5
4
3
2
1
2
4
2
1
1
2
1,2
3
4
5,6
VALVES
CIRCUITS
CO
2
Manifold: Change to carbonated or non-carbonated
water.
1. Rotate plunger 180° using a 5/32" Hex Key wrench.
2. Pull plunger up to get non-carbonated water.
3. Push plunger down to get carbonated water.
4. Turn plunger back 180° to lock.
5. Port 5 is not used.
Plain Water
(Plain Water Supply)
CA
RBONA
T
OR OUT
T
O
POS
T
-C
HI
L
L
Plain Water
(From
Pump to
Carbonator)
#1 #2 #3 #4 #5 #6
Syrup Lines
COLD PLATE
*EXTERNALLY CARBONATED UNITS: CARBONATOR IS REPLACED BY BY-PASS TUBE
FOR ASSISTANCE CALL (812) 246-7000
1
3
INTERNAL CARBONATOR TANK
(Optional)
PLUMBING: 3-1-1-1-2 MANIFOLDING
*OPTIONAL*
VARIETY VALVE ON #4
1 – WATER
(THRU COLDPLATE)
2 – SYRUP
(AMBIENT)
3 – SYRUP
(AMBIENT)
4 – SYRUP
(THRU COLDPLATE)
VALVES “SYRUP LINES NOT SHOWN”
P
R
E
-CHILL O
U
T
T
O
CA
RB
ONA
T
OR
6
5
4
3
2
1
2
4
2
1
1
1
7,8
6
7
4
VALVES
CIRCUITS
CO
2
Manifold: Change to carbonated or non-carbonated water.
1. Rotate plunger 180° using a 5/32" Hex Key wrench.
2. Pull plunger up to get non-carbonated water.
3. Push plunger down to get carbonated water.
4. Turn plunger back 180° to lock.
5. Port 5 is not used.
Plain Water
(Plain Water Supply)
CA
R
B
ONA
T
OR
OUT T
O
P
O
S
T
-C
HI
L
L
Plain Water
(From
Pump to
Carbonator)
#1 #2
#3 #4 #5 #6
Syrup Lines
COLD PLATE
*EXTERNALLY CARBONATED UNITS: CARBONATOR IS REPLACED BY BY-PASS TUBE
FOR ASSISTANCE CALL (812) 246-7000
1
8
7
3
1, 2, 3
#7 #8
STH14.book Page 174 Monday, May 4, 2009 1:48 PM
Содержание STH14
Страница 2: ......
Страница 8: ...8 Part Number STH14 5 09...
Страница 16: ...16 Part Number STH14 5 09 This Page Intentionally Left Blank...
Страница 20: ...20 Part Number STH14 5 09 DROP IN CT DIMENSIONS A B C D E F G H...
Страница 36: ...36 Part Number STH14 5 09 Rear View Rear Access for Drain Hose and Beverage Lines...
Страница 42: ...42 Part Number STH14 5 09 This Page Intentionally Left Blank...
Страница 88: ...88 Part Number STH14 5 09 This Page Intentionally Left Blank...
Страница 122: ...122 Part Number STH14 5 09 This Page Intentionally Left Blank...
Страница 150: ...150 Part Number STH14 5 09 This Page Intentionally Left Blank...
Страница 184: ...184 Part Number STH14 5 09 CF Drop In Series Wiring CF 1522 115V...
Страница 190: ...190 Part Number STH14 5 09 Flav R Pic FRP 250 Wiring FRP 250 NON CRUSHER WIRING DIAGRAM...
Страница 198: ...198 Part Number STH14 5 09 NGF 250 Wiring NGF 250 115V WIRING DIAGRAM...
Страница 199: ...Part Number STH14 5 09 199 quickdraw Wiring NFG 250 QD SV 250 QD 115V WIRING DIAGRAM...
Страница 201: ...Part Number STH14 5 09 201 S SV SVI 150 175 200 250 220 240V 50HZ C E...
Страница 202: ...202 Part Number STH14 5 09 Selectable Ice Wiring SV 200SCI SV 250SCI 115V 60HZ...
Страница 203: ......