Installation and Service Manual
15
MAINTENANCE SCHEDULE
Everyday
Dispensing Valves
For the pre-mix dispensing valve, run carbonated water
ONLY through the valve and dispense nozzle for 10
seconds. Turn syrup shut OFF, and block the dispense
nozzle base with a clean new napkin. Dispense carbon-
ated water only for a few seconds to fully fill the dispense
nozzle. Then unblock the dispense nozzle and flow
carbonated water for 10 seconds. Wipe external nozzle
surfaces with carbonated water, then turn syrup shut off,
ON. Clean other nearby surfaces with carbonated water or
cleaning solution.
Everyday
Drip pan and drain hose
Wash with mild detergent. Rinse with clean water.
Everyday
Quick disconnects
Wash with mild detergent. Rinse with potable water.
Weekly
Outside, dispenser cabinet
Wash with clean water and mild detergent. Wipe dry.
Every 3 months
Syrup circuits
Sanitize each syrup circuit. See ”Cleaning and Sanitizing
Procedure“.
Every 3 months
Water bath
Drain, melt ice and clean using detergent and brush; rinse
with potable water. Do not use water over 140°F (60°C).
Every 6 months
Condenser
Vacuum fins or use soft bristle brush (scrub brush).
Every 6 months
Air purifier filter (if equipped)
Replace.
NIGHTLY SHUTDOWN PROCEDURE
It is recommended that the following steps are followed to keep your Blade Tower clean and running properly;
1
Remove tower top piece to gain access to the
valves.
2
Turn the syrup shut off valve to the OFF position on
all valves (2 valves per tower).
3
Dispense carbonated water for 10 seconds from all
valves.
4
Leave valves off overnight and turn back on in the
morning for use.
USER MAINTENANCE