Serene Heated Ladder Towel Rail - Square Profile

Visible Supply Cord

As standard, the supply cord exits through the bottom of either 
the left or right hand mounting leg (see Figure 2 below). 

When installing the Towel Rail with the Supply Cord visible, the 
Cable Mounting Bracket (item 2) must be fitted to the wall with 
the Flat Washer (item 6) fitted inside the Bracket and with the slot 
in the Bracket facing downwards to clear the supply cord (see 
Figure 3 below).

Follow the instructions on the following page to install the Towel 
Rail with visible Supply Cord.

Figure 2: Visible Supply Cord

Cable
Mounting Bracket

Supply Cord

Supply Cord Grommet

Mounting Leg

Towel Rail Frame

Figure 3: Cable Mounting Bracket Fixing (for visible supply cord)

Cable Mounting 
Bracket

Slot facing downwards

Flat Washer

Wall Fixing

Screw (long)

Содержание LTRS7946

Страница 1: ...LTRS Series Serene Heated Ladder Towel Rail Square Profile Installation and Operating Instructions PRN5924 Rev 3 0 Nov 2008 edition...

Страница 2: ...nstallation 4 Regulations 4 Methods 4 Components 5 Visible Supply Cord 6 Concealed Supply Cord 8 Optional Spacers 10 3 Specifications 11 Dimensions 11 Electrical 11 Construction 11 4 Operation 12 5 Ma...

Страница 3: ...of this the appliance will feel hotter to the touch during warmer periods Also the insulation effect of towels will cause the operating temperature to increase slightly Do NOT use this appliance other...

Страница 4: ...e protected by an RCD the Heated Towel Rail can be plugged directly into a socket outlet otherwise permanent connection to the supply via a permanent connection unit is required On directly wired mode...

Страница 5: ...the following installation components Table 1 Installation Components Item Description Quantity 1 Standard Mounting Bracket 3 2 Cable Mounting Bracket 1 3 Mounting Base Extension 1 4 Leg Fixing Screw...

Страница 6: ...the wall with the Flat Washer item 6 fitted inside the Bracket and with the slot in the Bracket facing downwards to clear the supply cord see Figure 3 below Follow the instructions on the following pa...

Страница 7: ...ert the remaining three Mounting Brackets into the frame mounting legs Ensure the rectangular fixing slot in each Mounting Bracket faces downwards 6 Fit the Towel Rail frame leg onto the Cable Mountin...

Страница 8: ...the Supply Cord Grommet out of the slot in the bottom mounting leg and remove the grommet from Supply Cord 4 Feed the Supply Cord through the centre of the Cable Mounting Bracket see Figure 4 above 5...

Страница 9: ...e side of the stud to allow the Supply Cord to exit 9 Push the Mounting Base Extension into the 16mm hole firmly until the back of the flange is flush with the wall 10 Feed the Supply Cord into the wa...

Страница 10: ...re 6 Optional Spacer Installation Optional Spacer Wall Tiles Wall Visible Supply Cord Concealed Supply Cord Figure 7 Attaching Optional Spacer Optional Spacer Top Mounting Bracket Adhesive Dot 1 Befor...

Страница 11: ...75 80 W LTRSE4352 435mm 525mm 107mm 2 6 kg 35 40 W Electrical Supply 230 240 V 50 Hz single phase Insulation Class Class II Double Insulated Wiring 900mm 2 core supply cord and plug The plug may be re...

Страница 12: ...cleaners The supply cord on this product cannot be replaced without damaging the appliance If the supply cord becomes damaged in any way the appliance should be scrapped If the appliance is under warr...

Отзывы: