background image

DA

L  

19

65

Page 16/18

TECHNICAL DATA OF THE CR/41/ CONTROL UNIT

Power supply:

230Vac ±10% 50/60Hz

Motors power supply:

Two 230Vac single-phase motors, 200W+200W

Accessories power supply: 

24Vac 500mA

Flashing light power supply: 

230Vac, max 50W

Courtesy light power supply: 

230Vac, max 100W

Electric lock power supply: 

12Vac 15VA

Motors working time adjustment: 

from 0 to 120s

Pause time adjustment: 

from 4 to 120s

Phasing regulation in opening and closure: 

from 0 to 15s

Operating temperature: 

-20°C ÷ +70°C

Protection rating:

IP54

Dimensions (H x L x D) and weight:

270x212x118mm, 1,7Kg 

EXPANSION OF THE MINITRANSMITTER NUMBER

If the 32 minitransmitters that can be memorised in the built-in receiver are not sufficient, it is possible to increase them 
by inserting the SOG/4A receiver (that takes the number of minitransmitters to 40) eventually with the addition of the 
SOG/2A expansion (that takes the number of minitransmitters to 834).

After having inserted the SOG/4A receiver, all codes memorised in the built-in receiver must be deleted and all 
of the minitransmitters must be re-programmed on the new SOG/4A receiver, see specific instructions. The an-
tenna must be moved from the clamp on the control unit to the clamp found on the SOG/4A.

F1F1

F2

F2

ON

SW1

SW2

3 4 5 6 7 8

SOG/4

POWER

+

-

ON

PED

START STOP FOTO FOTO AP FINE CH FINE AP

DL9

DL8

DL10

1 2

9 10

11121314 1516171819 20

21

22

27

2526

2324

SET

BREAK

WORK

A

B

C

Com

+24

spia

RX

2829

2ND CHANNEL

OUTPUT:

AUXILIARY

CONTROL

ANTENNA

NC

C

NO

Channel 2 output (relay contact)

Max Voltage applicable= 

24Vac/dc

Max Current applicable=

 

1A

ELECTRIC LOCK

LIGHTS

OTHER AUTOMATIONS

OTHER

INSERT THE 
SOG/4A 
RECEIVER

1ST CHANNEL OUTPUT:

CONTROL UNIT

START CONTROL

PEDESTRIAN CONTROL

ON CR/41 -CLAMPS 1-2-

DISCONNECT THE POWER
SUPPLY BEFORE INTERVENING
ON THE CONNECTIONS

NO

K

IT

/A

9

 I

 E

Содержание KIT/A9

Страница 1: ...spected the following Reference Directives for CE marking Machinery Low Voltage Electromagnetic Compatibility General reference Standards Electrical Safety Electromagnetic Compatibility Emissions Electromagnetic Compatibility Immunity When installing the system as well as that mentioned previously please also respect General reference Standards Safety of electrical plants in general environments R...

Страница 2: ...RAI board Motor reducer without carter Electronic control unit with receiver incorporated Dual channel superminitele with pouch Electric key Pair of shock proof photocells Flashing light with antenna incorporated without internal electronicsfor flashing Elbow support CARTERS SOLD SEPARATELY A 69 Carter of ICE colour A 79 Carter of EMERALD colour A 89 Carter of DARK GREY colour A 99 Carter of DARK ...

Страница 3: ...um length of 19m section 2 5mm2 for lengths up to 31m for the flashing light section 0 75mm2 for maximum lengths of 3m section 1 5mm2 for lengths up to 19m for low voltage and current lines such as photocells control buttons electro mechanical key sensitive edges and other safety devices section 0 5mm2 for maximum length of 50m section 0 75mm2 for lengths up to 100m 4 Make the earth connection as ...

Страница 4: ...cording to the angle of opening of the gate position with re spect to the pillar respecting the measurements and drawings given below EXAMPLE FOR OPENING UP TO 120 B 200 A 300 400 MAX 120 BEFORE INSTALLING THE MOTORS DAL 1965 Page 4 18 Fig 1 Fig 2 Fig 4 KIT A9 I E INSTALLATION MEASUREMENTS 315 for 90 375 for 100 162 B A C 1 0 0 CORNER ATTENTION RESPECT THE MEASUREMENT C 100mm FOR CORRECT MOVEMENT ...

Страница 5: ...e toothed outlet of the shaft and fix it using the nut and washer Fig 7 Fig 6 Fig 8 110mm 100mm 6 fig 9 7 8 9 Position the articulated arm bracket on the gate as far away from the column as possible extending the arms to maximum and always respecting the measurement of as indicated in Fix the articulated arm bracket to the leaf suitably using screws or by welding Keeping the motor reducer released...

Страница 6: ... clockwise 180 Remove the handle by lifting it Lift the guard after having removed the two screw fasteners If it is necessary to act on the leaf manually e g if there is a power cut the following operations must be performed remove the electric power supply insert the key into the lock on the release lock and rotate it turn the release handle clockwise by 180 now the leaf can be moved manually MAN...

Страница 7: ...pen the lid from the opposite side proceed as follows ATTENTION This operation must be carried out before fixing the container to the wall Insert a flat tip screwdriver into the fixing recess of the hinges positioned on the rear of the base and lever on the attachment notch of the hinge itself pull the lid at the same time see Fig 1 Fig 1 Insert a flat tip screwdriver into the fixing recess of the...

Страница 8: ...correctly Close the lid using the appropriate screws Recommendations for connections in general rooms according to the Italian Standards IEC 64 8 1 Upstream from the system prepare an omnipolar isolating switch with distance of 3 mm or more between the contacts As an alternative use a 10A magnet circuit breaker switch 2 Make any type of connections always with the system not powered i e with the i...

Страница 9: ...onsumption exceeding 50mA use an appropriate additional external relay Sw1 Micro switches for setting the control unit see micro switches setting A Button used to enter programming SET B Button used to program times BREAK C Button used to program times WORK POWER Trimmer motor thrust regulation Sw2 Micro switches for setting the control unit see micro switches setting 20 DO NOT USE ADDITIONAL RELA...

Страница 10: ...ause different dilation of materials including those with which the motors are built For this reason it is recommended to control the regulation of the motor thrust at the start of the winter and the summer F1 F1 F2 F2 ON SW1 SW2 3 4 5 6 7 8 SOG 4 POWER ON PED START STOP FOTO FOTOAP FINECH FINEAP DL9 DL8 DL10 1 2 9 10 11121314 1516171819 20 21 22 27 2526 2324 28 29 SET BREAK WORK A B C Com 24 spia...

Страница 11: ...3 ON 4 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 ELECTRIC LOCK HAMMERING ATTENTION In case of varying the setting of the micro switches to make the new settings active it is necessary to switch the control unit off and on We recommend after having adjusted the micro switches to program the work times see control unit programming SW1 SW2 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 PEAK ON START UP 1 2 3 ON ...

Страница 12: ...n Open Close button Opening Photocell free from obstacles Closure photocell free from obstacles Stop button in normal state Pedestrian button pressed Open Close button pressed Regular connection between clamps 8 10 No jumper between clamps 8 10 Opening Photocell blocked out presence of an obstacle Closure Photocell blocked out presence of an obstacle Stop button pressed Pedestrian button in normal...

Страница 13: ...l the regulation of the motor thrust at the start of the winter and the summer ATTENTION If one or more parameters are varied programming must be repeated from the beginning In the programming procedure slowing has only been set in the closure phase but in normal functioning mode it is also introduced in the opening phase Press key C WORK once to start the opening phase of motor M1 M2 remains at a...

Страница 14: ...motor M1 slows down ATTENTION jump this point id slowing has been excluded DIP2 SW2 ON When the leaf is against the closing stop wait at least 5 seconds and then press key C WORK once The motor M1 is switched off and the control unit exits automatically from the programming phase and is ready for normal functioning PROGRAMMING OPEN GATE PAUSE TIME AUTOMATIC RE CLOSURE With the control unit powered...

Страница 15: ...r OG 02 and OG 04 do not have to be memorised just set the micro switches in the same sequence as that memorised DAL 1965 Page 15 18 LEARNING START CODE With the control unit powered and the gate closes press key A once SET to enter programming The DL10 LED starts to flash to indicate that the control unit is in the programming state Press the minitransmitter button e g on the left which wants to ...

Страница 16: ...mitters to 40 eventually with the addition of the SOG 2A expansion that takes the number of minitransmitters to 834 After having inserted the SOG 4A receiver all codes memorised in the built in receiver must be deleted and all of the minitransmitters must be re programmed on the new SOG 4A receiver see specific instructions The an tenna must be moved from the clamp on the control unit to the clamp...

Страница 17: ...A 24 V Temperature 10 60 C Dimensions 70 x 40 x 90 mm Weight 120 g RX RX THE POSITION OF THE CONTACT REFERS TO THE EXCITED RECEIVER 40 mm POSITION DIMENSIONS INSTALLATION RX ROUND YELLOW BULBS WITH 433 92 MHz BUILT IN ANTENNA 230 V RZ 20 RZ 99 SR 10 99 SUPPORT A OPTIONAL ELBOW NO 2 x 0 75 mm POWER SUPPLY RG58 ANTENNA CS 07 SR12 07 OPTIONAL CABLE CONNECTIONS ATTENTION IT IS RECOMMENDED TO POSITION ...

Страница 18: ... replace the internal antenna of the flashing light with an external SERAI OG 50 SR 25 50 Use of a SOG 4A receiver Replace the receiver incorporated with the SOG 4A board KIT A9 I E 02 18 120214 A4Vf r IS KIT A9 E WARRANTYCONDITIONS The company reserves the right to make any modifications without forewarning The conventional guarantee of SERAI product is valid for 24 months from the date of issue ...

Отзывы: