Regulate the "AMP", "RALL", "VELOC." potentiometers according to requirements.
With the control unit powered and
gate closed, press and release button P3 (PROGR)
, the DL6 LED starts to
flash to indicate that the control unit is found in the programming state.
Press and release key P2 (WORK), the wing connected to M1 starts to open.
When Motor M1 should start slowing (we recommend at least 50cm before the stop) press key P2 (WORK). The
motor M1 slows down.
ATTENTION: skip this point if slowing has been excluded ("RALL" potentiometer at maximum)
When the motor M1 reaches the opening stop, the motor shuts down automatically (motor shutdown control
intervention)
Press and release key P2 (WORK), the DL6 LED starts to flash quickly to indicate the start of the time difference
count when opening
When the desired phasing time has passed in opening (max 15s), press the P2(WORK) key and the motor M2
starts in opening mode and the DL6 LED starts to flash normally
ATTENTION: if you want a nil phase difference in opening, hold key P2 (WORK) down until M2 starts
When Motor M2 should start flowing (we recommend at least 50cm before the stop) press key P2 (WORK). The
motor M2 slows down.
ATTENTION: skip this point if slowing has been excluded ("RALL" potentiometer at maximum)
When the motor M2 reaches the opening stop, the motor shuts down automatically (motor shutdown control
intervention)
Press and release key P2 (WORK), the motor M2 starts to close
When Motor M2 should start flowing (we recommend at least 50cm before the stop) press key P2 (WORK). The
motor M2 slows down.
ATTENTION: skip this point if slowing has been excluded ("RALL" potentiometer at maximum)
When the motor M2 reaches the closing stop, the motor shuts down automatically (motor shutdown control
intervention)
Press and release key P2 (WORK), the DL6 LED starts to flash quickly to indicate the start of the time difference
count when closing
When the desired phasing time has passed in closing mode (max 15s), press the P2(WORK) key and the motor
M1 starts in closure mode and the DL6 LED starts to flash normally
ATTENTION: if you want a nil phase difference in closure, hold key P2 (WORK) down until M1 starts
When Motor M1 should start slowing (we recommend at least 50cm before the stop) press key P2 (WORK). The
motor M1 slows down.
ATTENTION: skip this point if slowing has been excluded ("RALL" potentiometer at maximum)
When the motor M1 reaches the closing stop, the motor shuts down automatically (motor shutdown control
intervention)
The control unit automatically leaves the programming phase,
switching the DL6 LED off
and is ready for normal
functioning
MANUAL PROGRAMMING FOR GATE WITH TWO WINGS (DIP1 SW1 OFF)
The installer sets work times, slowing point and phase difference time according to requirements
Regulate the "AMP", "RALL", "VELOC." potentiometers according to requirements.
With the control unit powered and
gate closed, press and release button P3 (PROGR)
, the DL6 LED starts to
flash to indicate that the control unit is found in the programming state.
Press and release key P2 (WORK), the wing connected to M1 starts to open.
When Motor M1 should start slowing (we recommend at least 50cm before the stop) press key P2 (WORK). The
motor M1 slows down.
ATTENTION: skip this point if slowing has been excluded ("RALL" potentiometer at maximum)
When the motor M1 reaches the opening stop, the motor shuts down automatically (motor shutdown control
intervention)
Press and release key P2 (WORK), the motor M1 starts to close
When Motor M1 should start slowing (we recommend at least 50cm before the stop) press key P2 (WORK). The
motor M1 slows down.
ATTENTION: skip this point if slowing has been excluded ("RALL" potentiometer at maximum)
When the motor M1 reaches the closing stop, the motor shuts down automatically (motor shutdown control
intervention)
The control unit automatically leaves the programming phase,
switching the DL6 LED off
and is ready for normal
functioning
MANUAL PROGRAMMING FOR GATE WITH SINGLE WING (DIP1 SW1 ON)
The installer sets work times and slowing point according to requirements
DA
L
19
65
Page 8/12
C
R
/4
1
/2
4
I
E
MANUAL PROGRAMMING VIA REMOTE CONTROL
When a remote control has been programmed, it is possible to perform
manual programming of the remote
control key replacing button
P2 (WORK) of the control unit
To do this, follow the same procedures mentioned above, only instead of entering programming by pressing button
P3 (PROGR),
press P3 (PROGR) + P2 (WORK) at the same time
.