background image

DA

L  

19

65

Page 7/12

PROGRAMMING THE CONTROL UNIT

The programming must be carried out point by point. In the case of errors during this phase, it is necessary to 
proceed with new programming, which will delete the first.

Before programming, the system must be complete with all electrical devices and safety devices connected 
(buttons, photocells, flashing lights etc.).
Check their correct functioning:

 All signal LEDs of the NC inputs (stop, photocells, etc) are on.
 All signal LEDs of the NO inputs (start, pedestrian) are off.

In the case of anomalies check and remove the cause.

ATTENTION:

 The normally closed (NC) inputs that are not used must be jumpered. 

Regulate the "AMP", "RALL", "VELOC." potentiometers according to requirements.
With the control unit powered, 

press and hold down button P3 (PROGR)

 until the motors start the closure 

action (about 10s). If the gate is already closed, the board makes this search anyway, forcing on the stops for a 
few seconds. The DL6 LED starts to flash to indicate that the control unit is in the programming state.
After the gate is closed, the M1 motor wing is opened and after about 3 s, the wing connected to M2 is also 
opened.
When the wings reach the stops, the motors shutdown automatically. In this way, the run is calculated and the 
slowing points are defined (about 4s before the mechanical stops) which are the same in opening and closure 
modes.
Successively, the gate automatically closes with phase difference between the wings of about 3 seconds and 
performs slowing before stopping against the stops.
The control unit automatically leaves the programming phase, 

switching the DL6 LED off

 and is ready for 

normal functioning

ATTENTION:   - If any potentiometer is varied, the programming must be repeated.

The functioning time of the motors is controlled by two independent digital timers. If any control interrupts the run of 
the wing before the end, the timer stops and the time passed is memorised. The appliance is therefore able to 
establish the partial work time necessary to terminate the wing run, with a certain approximation, always slowing in 
the programmed point. 

ATTENTION:    

The lack of power supply to the circuit board (network or battery) causes the loss of the memorised 
position. Successively to commissioning, a start control is for opening without activation of the 
amperometric control, therefore the gate re-aligns on the opening stops.

AUTOMATIC PROGRAMMING FOR GATE WITH TWO WINGS (DIP1 SW1 OFF)

Automatically sets work times, slowing point and phase differences of the wing when opening and closing

Regulate the "AMP", "RALL", "VELOC." potentiometers according to requirements.
With the control unit powered, 

press and hold down button P3 (PROGR)

 until the motor starts the closure 

action (about 10s). If the gate is already closed, the board makes this search anyway, forcing on the stop for a 
few seconds. The DL6 LED starts to flash to indicate that the control unit is in the programming state.
After the gate is closed, the wing of motor M1 is opened and on arrival against the stop, the motor shuts down 
automatically. The run is calculated and the slowing points are defined in this way (about 4s before the 
mechanical stroke) which are the same in opening and closure modes.
Successively, the gate closes automatically, slowing before stopping against the stop.
The control unit automatically leaves the programming phase,

 switching the DL6 LED off 

and is ready for 

normal functioning

AUTOMATIC PROGRAMMING FOR GATE WITH SINGLE WING (DIP1 SW1 ON)

Automatically sets work times and wing slowing point

C

R

/4

1

/2

4

 I

 E

CONTROLS MODIFICATION

It is possible to modify the functioning of the 1 and 2 inputs in this way:
- Input 2 functions as "START": with control unit off, press and hold keys P3 (PROGR) and P2 (WORK) 

simultaneously and apply power supply.

- Input 2 functions as "CLOSE only": with control unit off, press and hold keys P3 (PROGR) and P1 (PAUSE) 

simultaneously and apply power supply.

- Input 1 functions as "PEDESTRIAN": with control unit off, press and hold keys P2 (WORK) and P1 (PAUSE) 

simultaneously and apply power supply.

- Input 1 functions as "OPEN only": with control unit off, press and hold keys P1 (Pause) and P2 (WORK) and P3 

(PROGR) simultaneously and apply power supply.

Содержание CR/41/24

Страница 1: ...hibits the realisation of these types of plants by unqualified staff On realisation of its own products SERAI has respected the following Reference Directives for CE marking machinery 2006 42 EEC low...

Страница 2: ...en the lid from the opposite side proceed as follows ATTENTION This operation must be carried out before fixing the container to the wall Insert a flat tip screwdriver into the fixing recess of the hi...

Страница 3: ...le to the rest of the system to a minimum The control unit must be fixed via the cable passage holes facing downwards NO NO YES 6 8 mm Recommendations for connections in general rooms 1 Upstream from...

Страница 4: ...meter at maximum the amperometric control is excluded RALL POTENTIOMETER speed regulation during the slowing phase with the potentiometer at maximum slowing is excluded VELOC POTENTIOMETER regulation...

Страница 5: ...ontrol for electric lock SERAI M 83 1 With SW2dip2 ON control with the gate open indicator light function Input for the connection of the antenna for the built in receiver 33 BRAIDING EARTH 34 ANTENNA...

Страница 6: ...ter ATTENTION in this case there may be difficulties on start up if the force is regulated low 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 CLAMPS 11 12 FUNCTIONING MODE Open gate indicator light outpu...

Страница 7: ...essary to terminate the wing run with a certain approximation always slowing in the programmed point ATTENTION The lack of power supply to the circuit board network or battery causes the loss of the m...

Страница 8: ...key P2 WORK down until M1 starts When Motor M1 should start slowing we recommend at least 50cm before the stop press key P2 WORK The motor M1 slows down ATTENTION skip this point if slowing has been e...

Страница 9: ...s is set by regulating the AMP potentiometer The intervention of the amperometric control can be more or less rapid depending on the sensitivity set with the SW3 jumper The gate inverts movement for a...

Страница 10: ...2 OG 04 as pedestrian control the others do not have to be memorised OG 02 and OG 04 just set the micro switches in the same sequence as that memorised LEARNING START CODE With the control unit powere...

Страница 11: ...ALL AMP ON 1 2 4 3 SW1 ON 1 2 4 3 SW2 25 26 F2 F2 F3 F3 F1 F1 F4 F4 SW3 LED DL6 DL1 PED DL2 START DL3 STOP DL4 FOTO DL5 FOTOAP DL7 COSTA PAUSA LAVORO PROGR BATTERY Power supply transformer 230 20 Vac...

Страница 12: ...ntiometer regulates the amperometeric control intervention which intervenes every time that the gate stops moving for a brief period of time due to external factors such as gusts of wind for example T...

Отзывы: