PROGRAMMING THE CONTROL UNIT
The programming must be carried out point by point. In the case of errors during this phase, it is necessary to
proceed with new programming, which will delete the first.
Before programming, the system must be complete with all electrical devices and safety devices connected
(buttons, photocells, flashing lights etc.).
Check their correct functioning:
All signal LEDs of the NC inputs (stop, photocells, etc) are on.
All signal LEDs of the NO inputs (start, pedestrian) are off.
In the case of anomalies check and remove the cause.
ATTENTION:
The normally closed (NC) inputs that are not used must be jumpered.
Regulate the "AMP", "RALL", "VELOC." potentiometers according to requirements.
With the control unit powered,
press and hold down button P3 (PROGR)
until the motors start the closure
action (about 10s). If the gate is already closed, the board makes this search anyway, forcing on the stops for a
few seconds. The DL6 LED starts to flash to indicate that the control unit is in the programming state.
After the gate is closed, the M1 motor wing is opened and after about 3 s, the wing connected to M2 is also
opened.
When the wings reach the stops, the motors shutdown automatically. In this way, the run is calculated and the
slowing points are defined (about 4s before the mechanical stops) which are the same in opening and closure
modes.
Successively, the gate automatically closes with phase difference between the wings of about 3 seconds and
performs slowing before stopping against the stops.
The control unit automatically leaves the programming phase,
switching the DL6 LED off
and is ready for
normal functioning
ATTENTION: - If any potentiometer is varied, the programming must be repeated.
The functioning time of the motors is controlled by two independent digital timers. If any control interrupts the run of
the wing before the end, the timer stops and the time passed is memorised. The appliance is therefore able to
establish the partial work time necessary to terminate the wing run, with a certain approximation, always slowing in
the programmed point.
ATTENTION:
The lack of power supply to the circuit board (network or battery) causes the loss of the memorised
position. Successively to commissioning, a start control is for opening without activation of the
amperometric control, therefore the gate re-aligns on the opening stops.
AUTOMATIC PROGRAMMING FOR GATE WITH TWO WINGS (DIP1 SW1 OFF)
Automatically sets work times, slowing point and phase differences of the wing when opening and closing
Regulate the "AMP", "RALL", "VELOC." potentiometers according to requirements.
With the control unit powered,
press and hold down button P3 (PROGR)
until the motor starts the closure
action (about 10s). If the gate is already closed, the board makes this search anyway, forcing on the stop for a
few seconds. The DL6 LED starts to flash to indicate that the control unit is in the programming state.
After the gate is closed, the wing of motor M1 is opened and on arrival against the stop, the motor shuts down
automatically. The run is calculated and the slowing points are defined in this way (about 4s before the
mechanical stroke) which are the same in opening and closure modes.
Successively, the gate closes automatically, slowing before stopping against the stop.
The control unit automatically leaves the programming phase,
switching the DL6 LED off
and is ready for
normal functioning
AUTOMATIC PROGRAMMING FOR GATE WITH SINGLE WING (DIP1 SW1 ON)
Automatically sets work times and wing slowing point
C
R
/4
1
/2
4
I
E
CONTROLS MODIFICATION
It is possible to modify the functioning of the 1 and 2 inputs in this way:
- Input 2 functions as "START": with control unit off, press and hold keys P3 (PROGR) and P2 (WORK)
simultaneously and apply power supply.
- Input 2 functions as "CLOSE only": with control unit off, press and hold keys P3 (PROGR) and P1 (PAUSE)
simultaneously and apply power supply.
- Input 1 functions as "PEDESTRIAN": with control unit off, press and hold keys P2 (WORK) and P1 (PAUSE)
simultaneously and apply power supply.
- Input 1 functions as "OPEN only": with control unit off, press and hold keys P1 (Pause) and P2 (WORK) and P3
(PROGR) simultaneously and apply power supply.