OPERATION
36
ALARM_STATE
Long 1
(4-byte)
Byte 1
Bit 0
Drive fault
Bit 1
Out of calibration range
Bit 1 (only pumps with HLE)
Bit 2
Setpoint cannot be achie-
ved
Bit 3
Fault stroke sensor
Bit 4
No stroke detection
Bit 5
Reserved
Bit 6
Drive too slow
Bit 7
Reserved
Bit 8
Diaphragm rupture
Bit 9
Pre-alarm level
Bit 10 Dry run level
Bit 11 Mains voltage too high
Bit 12 Mains voltage too low
Bit 13 no flow, only for active
flow rate monitoring
Bit 14 Flow rate too low
Bit 15 Pulse memory overflow
Bit 16 Overtemperature, only
stepper motor pump
Bit 17 Service time exceeded
Bit 18 SD card fault
Bit 19 Analogue signal > 20 mA
Bit 20 Analogue signal < 4 mA
Bit 21 Analogue signal > 25mA
Bit 22 Reserved
Bit 23 Reserved
Bit 24 Reserved
Bit 25 Reserved
Bit 26 Reserved
Bit 27 Reserved
Bit 28 Reserved
Bit 29 Reserved
Bit 30 Reserved
Bit 31 Reserved
No. Module Name
Data type Function
Comment