To wire the Wake on Alarm feature with a Diagnostic Button:
1
On the Diagnostic Button cable, cut the green wire just before it enters the socket. See Figure 8.
2
Extend and connect the green wire to an input wire on the Signals harness.
3
Configure the DVR Alarm settings as described above.
Diagnostic Button Installation (Optional)
When installed, press the Diagnostic Button to cause an alarm event to be recorded by the DVR.
To install the Diagnostic Button, see the
Diagnostic Button Installation Guide
, part number 700-0142.
RGY Illuminator Installation (Optional)
When installed, the RGY Illuminator LED displays DVR status conditions.
To install the RGY Illuminator, see the
RGY Illuminator Installation Guide
, document number 700-0139.
Important:
If you are using the Diagnostic Button and cable, and require the Wake on Alarm feature, the
Diagnostic Button cable must be rewired as shown in Figure 8.
Figure 8
Wiring Alarm Button and Signal harnesses for Wake on Alarm